AG-BZ003-B Patient Monitor For Hospital ICU and General Diagnosis

Write a review
AG-BZ003-B
In stock
Price: click login to view
Get a quotation upon your custom quantity
AG-BZ003-B Patient Monitor For Hospital ICU and General Diagnosis Specification 1) 12V DC  power supply for ambulance use 2) An optional  HDMI output  eases observation from a long distance. Dimension and Weight Dimension: 210mm*130mm*75mm Weight: ...
+

Minimum quantity for "AG-BZ003-B Patient Monitor For Hospital ICU and General Diagnosis" is 1.

Port: Shanghai,China
Payment
Share to

AG-BZ003-B Patient Monitor For Hospital ICU and General Diagnosis

Specification

1)12V DC power supply for ambulance use
2) An optional HDMI output eases observation from a long distance.

Dimension and WeightDimension:210mm*130mm*75mm
Weight: 1kg(excluding accessories)
Power SupplyVoltage: AC100~240V, 50/60HZ
Adapter: Output 9VDC, 5A
Display7" color TFT LED  
Resolution: 800*480 pixels
BatteryType: Rechargeable lithium battery 7.4V/2200mAh
Charge Cycle: ≥500 times
Working time: 2-3 hours (optional larger battery for 4-5 hours)
Recorder (Option)Method: USB External Thermal printer
Paper width: 50 mm (1.97 in)
Printing speed: 12.5/ 25/ 50 mm/s
Trace: Max. 3 tracks
Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording
Alarm  Level: Low, medium and high
Indication: Auditory and visual Alarm volume adjustable
Alarm pause time: 1min, 2min
Parameter alarm type: Latch/ Unlatch
Input DeviceTouch screen (standard) Touch pen (standard)
System Output & Extensible Interface Ethernet Network: 1 standard RJ45 socket
USB Port: 1
Video Output: 1 HDMI port (option)
Operating Environment Temperature:  5 ~ 40 ℃
Humidity:  15% ~ 80% (non-condensing)
Atmosphere pressure:  86 KPa ~ 110 KPa
Transportation and Storage Environment Temperature:  -20~50 ℃
Humidity:  10%~90%  (non-condensing)
Atmosphere pressure:  86 KPa ~ 110 KPa
Safety IEC60601-1 Approved, CE marking according to MDD93/42/EEC With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing Trend: 2160 hours
ARR events: 128 groups of ARR events and associated waveform
NIBP measurement reviewing: 2000 groups
Waveform review: 2 hours
Alarm event: 2000 groups of parameter alarms events and associated parameter
Heart Rate Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1% or ± 1bpm, whichever is greater
NIBPMethod: Oscillometric
Measure mode: Manual, Auto, STAT
Measure Interval in AUTO Mode: 1~480 min
STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
Static pressure accuracy: ±3mmHg
Resolution: 1mmHg
Accuracy: Maximum Mean error ±5mmHg   
Maximum Standard deviation: ≤8mmHg      
Overpressure Protection: Dual protection via software & hardware
NIBPMeasure and Alarm Range:  Adult: SYS:  30 ~ 270 mmHg
           DIA:  10 ~ 220 mmHg     
           MEAN:  20 ~ 235 mmHg
Pediatric: SYS:  40 ~ 235 mmHg
                DIA:  10 ~ 220 mmHg     
              MEAN:  20 ~ 225 mmHg
Neonate:SYS:  30 ~ 135 mmHg
               DIA:  10 ~ 110 mmHg     
             MEAN:  20 ~ 125 mmHg

Model Configuration

Standard Config.With 7’ LED, Touch Screen
SpO2+NIBP+PR+ TEMP
Optional Config.Nellcor SpO2, Masimo SpO2, Suntech NIBP, Infrared thermometry
Optional Accessories:Printer, HDMI Output, Wall-mounting, Trolley, Bed Hanger