High-Frequency Mobile Digital C-arm System AG-D112B
High-Frequency Mobile Digital C-arm System AG-D112B
Specification:
I. Usage:
Orthopedics, General Surgery, Pain management, Traumatology, and so on
Surgery: Removing foreign body, implanting pace maker, partial radiography, local photography, and other surgeries
II. Features
1. High-quality combined high-frequency high voltage X-ray generator reduces x-ray dose to the body
2. With the function of kV, mA automatically tracks (ABS) in fluoroscopy to make the image brightness and clearness
3. Real-time continuous Pulse Fluoroscopy with a low dose, but meet operation demand with clearness image
4. Human graphical LCD touch screen, intelligent and fast operation
5. A unique hand-held controller design, convenient to operate
6. Toshiba image intensifier and Medical Mega-pixels digital CCD camera, the quality is stable and reliable, and image clarity
7. Powerful digital graphic workstation with the standard configuration of DICOM 3.0 connected to network perfectly, and perfect software
8. Unique design of electric auxiliary support arm is more security for using
9. New C-arm frame with a compact appearance, and easy to operate
10. Digital radiography with a powerful processing program
11. Automatically store the last image of fluoroscopy to advantage diagnosis
III. Configuration
Item | Quantity |
The main frame of the C-arm | 1 |
X-ray generator and high-frequency inverter power supply | 1 |
Toshiba 9’’ three fields image intensifier | 1 |
Medical Mega-pixels digital CCD camera | 1 |
Digital Acquisition and Processing workstation | 1 |
19’’ LCD monitor | 1 |
24’’ LCD monitor | 1 |
Imported mini groove grid | 1 |
Electrically adjustable collimator | 1 |
Hand controller | 1 |
Red light cross localization | 1 |
Fluoroscopy/ Photography
High-Frequency Inverter Power Supply | Output Power:5kW Inverter Frequency:40kHz |
Automatic Fluoroscopy | Tube Voltage: 40kV~120kV(automatic adjustment) Tube Current:0.3mA~4mA(automatic adjustment) |
Manual Fluoroscopy | Tube Voltage:40kV~120kV(continuous adjustment) Tube Current:0.3mA~4mA(continuous adjustment) |
Pulsed Fluoroscopy | Tube Voltage:40kV~120kV(continuous adjustment) Tube Current:0.3mA~30mA (continuous adjustment,Intelligent control of pulse frequency) |
Photography | Tube Voltage:40 kV-120 kV mA:25-100mA mAs:1-180 mAs |
Plate holder Size | 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) |
X-ray Tube
X-ray Tube Special for High Frequency
Fixed anode Dual-focus: 0.6/1.8mm
Anode Thermal Capacity:35kJ
Video System
Image Intensifier | TOSHIBA 9" image intensifier |
CCD Video camera | Medical Mega-pixels digital CCD camera |
Monitor | 19’’ LCD monitor and 24’’ LCD monitor |
Work Station Software | Storage without damage, multi-images display, image W/L real-time adjustment, grayscale switch, region of interest balance, GAMMA correction, flip, noise reduction, intensifying, smoothing, sharpening, compression, zoom in, measurement, remark, picture-text typeset print, expert template, DICOM image transmit, DICOM image print, cine loop, image imprinting, Worklist registration, etc. |
Structural performance
Directive wheel | Direction wheel 360°rotation, main wheel ±90°rotation |
C-arm | Electric Ascending & Descending of pillar movement:400mm Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis: ±15° Slip-on orbit: 120°(+90°~ -30°) SID: 1000mm Opening: 760mm Arc depth: 670mm |
Packing Details:
Packing size: 2440*1100*1420mm,
NW: 440kg,
GW: 575kg
No reviews found