BJMB-001 Spirometer

Write a review
*BJMB-001
Out of stock
Price: click login to view
Get a quotation upon your custom quantity
BJMB-001 Spirometer Specification 1.The portable pulmonary function measurement instrument can be used tomeasure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilatory Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)...

Minimum quantity for "BJMB-001 Spirometer" is 1.

Port: Shanghai,China
Payment
Share to

BJMB-001 Spirometer

Specification

1.The portable pulmonary function measurement instrument can be used tomeasure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilatory Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)
2.Adopting pressure-flow sensor, sensitive, precise, easy to launder, clean and durable
3.All parameters can be displayed on the oversized screen(320x240), built-in memory can store maximum 300 cases of patient measurement results
4.The instrument can calibrate automatically, all English operation, more convenient to operate
5.110mm thermal printer built-in, can print out a clear clinical report, predicted value, measured value
6.Measurement of breathing time: VC time 50 seconds, FVC measuring time 25 seconds, MVV time 12 seconds, in favor of the coordination between patients and the device 
7.Compact and flexible


VCVital Capacity
ERVExpiratory Reserve Volume
IRVInspiratory Reserve Volume
TVTidal Volume
ICInspiratory Capacity
FVCForced Vital Capacity
FEV0.5Forced Expiratory Volume in 0.5s
FEV1.0Forced Expiratory Volume in 1s
FEV3.0Forced Expiratory Volume in 3s
FEV1.0%GForced Expiratory Volume in 1s/Forced Vital Capacity
FEV1.0%TForced Expiratory Volume in 1s/Vital Capacity
FEV3.0%GForced Expiratory Volume in 3s/Forced Vital Capacity
FEV3.0%TForced Expiratory Volume in 3s/Vital Capacity
VextVolume of Expiration
Ex TimeExpiratory Time
MMFThe maximum mid-expirator flow, same as MMEF
PEFPeak Expiratory Flow
MEF75Maximum Expiratory Flow when 75% FVC remains, same as FEF25
MEF50Maximum Expiratory Flow when 50% FVC remains, same as FEF50
MEF25Maximum Expiratory Flow when 25% FVC remains, same as FEF75
FIVCForced Inspired Vital Capacity
FIV0.50.5s Forced Inspired Volume
FIV1.01s Forced Insipred Volume
FIV1.0/FVCForced Inspired Volume in 1s/Forced Vital Capacity
FIV1.0/FIVCForced Inspired Volume in 1s/Forced Inspired Vital Capacity
PIFPeak Inspiratory Flow
MIF50%Inspiratory Flow in 50% Inspired Capacity
MVVMaximum Voluntary Ventilation
RRRespiratory rate per minute
TVTidal Volume in MVV measurement

Optional: Mouth