4D Portable Robust Cardiovascular Ultrasound Equipment DW-P8

Write a review
DW-P8
In stock
Price: click login to view
Get a quotation upon your custom quantity

Portable Ultrasound Machine Manufacturer

Main screen 15 inches

Full Angle medical HD display

Comprehensive ultrasound diagnostic solutions

Automatic Image Optimization

CW, TDI function for cardiac

Elastography function

+

Minimum quantity for "4D Portable Robust Cardiovascular Ultrasound Equipment DW-P8" is 1.

Port: Shanghai,China
Payment
Share to

4D Portable Robust Cardiovascular Ultrasound Equipment DW-P8

This portable cardiovascular ultrasound machine comes with an ultrasonic host operating system with Windows 7 operating system, widely applied to abdominal, OB/GYN, Cardiac, Urinary, Small Parts, Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc.

Besides, it has various probes for different diagnoses, including convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, cardiac probe, and 4D volume probe.

1

Summary of main specifications and system of portable type all digital color Doppler ultrasound

1.2

Carotid artery intima measurement thickness(IMT )

1.3

Automatic spectral envelope measurement

1.4

Full digital transmission and reception of beam synthesizer

1.5

Color Doppler imaging ( C )

Pulse-Doppler Imaging ( PW )

Coherent Contrast imaging ( CCI )

Continuous-wave Doppler imaging ( CW )

1.6

B/C/D Real-time three synchronous imaging

1.7

Power Doppler imaging ( PDI )

Direct power Doppler imaging ( DPDI )

M mode imaging
Anatomic M mode imaging
Color Doppler M mode imaging

1.8

Elastography

Tissue Doppler imaging ( TDI )

Strain rate imaging (SRI)

Tissue harmonic imaging ( THI )

Fusion harmonic imaging ( FHI )

Speckle Reduce imaging ( SRI )

Panoramic imaging
Deflection imaging
Trapezoidal imaging

1.9

Adaptive velocity optimization

1.91

Freehand 3D

Real-time 3D imaging ( 3D/4D )

DICOM3.0

Monitor 

 ≥15 inches, high definition ultrasonic display

Battery

Built-in rechargeable battery

Physical clipboard

Save the image on the left side of the screen, which can be directly saved or deleted.

1.92

The system has the function of an on-the-spot upgrade

Presupposition

for different inspections of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation.

Probe interface

 2

Language

Chinese/English/German/Russian/Spanish/French/Arabic/Vietnamese/Portuguese/Indonesian

Depth 

≥360mm

1.93

Extended imaging

2

Probes

2.1  Convex probe

Fundamental Frequency : 2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,

Harmonic Frequency:4.0MHz/4.6MHz/5.0MHz

2.2 Linear probe

Fundamental Frequency :4.0MHz /4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz /10.0MHz /12.0MHz/13.3MHz ,

Harmonic Frequency :8.0MHz/9.2MHz/10.0MHz

2.3 Trans-vaginal probe

Fundamental Frequency :3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz ,

Harmonic Frequency :6.0MHz/7.0MHz/8.0MHz

2.4 Micro-convex probe

Fundamental Frequency :3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz ,

Harmonic Frequency:6.0MHz/7.0MHz/8.0MHz

2.5Cardiac probe

Fundamental Frequency : 1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz ,

Harmonic Frequency:3.4MHz/3.8MHz/4.2MHz

2.6 4D Volume probe

Fundamental Frequency :2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz ,

Harmonic Frequency:4.0MHz/5.0MHz/6.0MHz,

3

2D imaging mode

Gain 

 0-100, Step 2 adjustable

TGC

8 segments adjustable

Maximum focus point 

≥7, which can be moved throughout the whole process.

Speckle reduction 

 0-5, 5 level

Space Synthesis

0-2, 2 levels ( Liner probe: 3 levels,  cardiac probe:0 )

Dynamic

30-180, 35 levels, step 5 adjustable

Line density

low、middle、high, 3 level

Frame correlation

 0-4,4 level

Noise reduction

 0-5,5 level

Edge Enhancement

0-5,5 level

3.1

Sound power: 2-10, 9 level

Greyscale : 0-67, 67 level

False-color : 0-67 , 67 level

Image style: Soft-Comparison, 2 level

3.2

The screen has a real-time display of voice power, probe frequency, dynamic range, pseudocolor, grayscale, and other 11 parameters that can be adjusted

4

Color Doppler imaging mode

4.1

Blood gain : 0-100, Step 2

4.2

Parameter display: Velocity、Variance

4.3

B-Restrain ( B/W restrain )  : 0-7, 7 level

4.4

Speed Through : 0-8, 8 level

4.5

Sampling number: 6-24, 7 level

4.6

Blood flow preferred : 0-8, 8 level

4.7

Filtering: 1-6, 6 level

4.8

Sound power: 2-6, 4 level

4.9

Noise reduction : 0-4, 4 level

4.10

Smooth treatment : 0-4,  4 level

4.11

Frame correlation : 0-6 ,  6 level

4.12

Chromatography ( Blood flow graph )  : 0-37 ,  37 level

4.13

Line density: Low-Middle-High,  3 level

4.14

Frequency: 4 level adjustable

4.15

Velocity: Minimum 0.4K, Maximum 40.5K

Convex probe : 0.4K-4.3K-38.5K

Linear probe : 0.4K-14.7K-39.0K

Trans-vaginal probe : 0.4K-7.8K-39.7K

Volume probe: 0.4K-4.2K-34.8K

Micro-convex probe : 0.4K-10.3K-40.5K

cardiac probe: 0.4K-7.8K-39.7K

 PS : 

The frequency of the probe changes and the frequency value changes

Frame rate changes with speed

5

Pulse wave Doppler ( PW )

5.1

Gain : 0-100, Step 2

5.2

Spectrum envelope function: real-time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR, and so on. Can wake up or close

5.3

Sample volume : 0.5mm~30mm

5.4

Blood angel: -75—75 degree, Step 5

5.5

False-color : 0-67,67 level

5.6

Dynamic range: 20-40,4 level

5.7

Filter : 0-9,9 level

5.8

Smooth treatment: 1-4,4 level

5.9

Sound power: 2-5,4 level

5.10

Volume : 0-100, 10 level , Step 10

5.11

Audio filtering : 0-4,  4 level

5.12

Baseline : -1.0~1.0,

5.13

Grey map : 0-67,  67 level

5.14

Scan velocity: 100-500, 6 level

5.15

PRF:Minimum 0.5K , Maximum 87.5K

Convex probe : 0.5K-4.3K-63.3K

Linear probe : 0.5K-14.5K-78.4K

Trans-vaginal probe : 0.5K-8.1K-78.4K

Volume probe : 0.5K-4.2K-53.8K

Micro-convex probe : 0.5K-10.3K-81.1K

Cardiac probe : 0.5K-4.3K-87.5K

5.16

Frequency: 4 level

 PS : 

The frequency of the probe changes and the PRF value changes

 PS : 

The frequency of the probe changes and the frequency value changes

6 

Continuous Wave Doppler ( CW )

6.1

Support probe: Cardiac probe

6.2

Adjustment of B mode parameters is switchable

6.3

Gain : 0-100, Step 2

6.4

The sampling line position is adjustable

6.5

PRF:0.9K~36.1K

6.6

Baseline : -1.0~1.0

6.7

Blood angel: -75~75 degree

6.8

Grey map : 0-67

6.9

Scan velocity: 100-300

6.10

False-color : 0-67

6.11

Dynamic range: 20-40

6.12

Filtering : 0-9 , 9 level

6.13

Smooth treatment: 1-4

6.14

Frequency : 2.0MHz/2.3MHz/2.5MHz/3.0MHz , 4 level adjustable

6.15

Sound power: 2-5

6.16

Volume : 0-100

6.17

Audio Filtering : 0-4

☆7 

Anatomical M imaging

7.1

Support probe: Convex probe, Linear probe, Cardiac probe

7.2

Adjustment of B mode parameters is switchable

7.3

Gain : 0-100, Step 2

7.4

M Sampling line angle is adjustable

7.5

M Sampling line length is adjustable

7.6

Sampling line : 3, Can be displayed or hidden separately

☆8

Blood flow M model ( MC )

8.1

Adjustment of B mode parameters is switchable

8.2

Gain : 0-100, Step2

8.3

MC Sampling line angle is adjustable

8.4

MC Sampling line length is adjustable

8.5

Frequency: 4 level

8.6

Sampling number: 6-24

8.7

Speed through : 0-8, 8 level

8.8

Scan velocity: 150-500

8.9

Frame correlation : 0-6, 6 level

8.10

Filtering: 1-6, 6 level

8.11

Blood flow preferred : 0-8, 8 level

8.12

Smooth treatment : 0-4,4 level

8.13

Map : 0-37, 37 level

☆9 

Elastography

9.1

Adjustment of B mode parameters is switchable

9.2

Gain : 0-100, Step 2

9.3

B/E, Double real-time display on the same screen

9.4

Probe displacement curve display: Up/Down

9.5

Pressure indicator bar display

9.6

Frequency: 8-9 level, Adjustable; According to the probe display

9.7

Noise reduction : 0-2, 2 level

9.8

Frame correlation : 0-3, 3 level

9.9

Comparison : 0-13, 13 level

9.10

False-color : 0-3 ,  3 level

9.11

Don’t support cardiac probe

☆10 

Tissue Doppler imaging ( TDI )

10.1

Support probe: Cardiac probe

10.2

Adjustment of B mode parameters is switchable

10.3

Gain : 0-100, step 2

10.4

ROI area adjustable

10.5

Sampling number: 6-24

10.6

Velocity : 0.4K-8.0K

10.7

Frame correlation : 0-6, 6 level

10.8

Tissue preferred : 0-7, 7 level

10.9

Frequency : 2.0MHz/2.3MHz/2.5MHz/3.0MHz

10.10

Support color reversal

☆11 

Strain rate imaging

11.1

Support probe: Cardiac probe

11.2

Adjustment of B mode parameters is switchable

11.3

ROI area adjustable

11.4

Gain : 0-100, Step 2

11.5

Sampling number: 6-24, 6 level

11.6

Axial average: 1-4,  4 level

11.7

Velocity: 0.4K-8K

11.8

Frame correlation : 0-6 ,  6 level

11.9

Tissue optimization : 0-7 , 7 level

☆12 

Panoramic imaging

12.1

Support probe: Linear probe

12.2

Speckle Reduction : 0-5, 5 level

☆13

Deflection imaging

13.1

Support probe: Linear probe

13.2

Adjustment of B mode parameters is switchable

13.3

Deflection angel: 8 level

13.4

Speckle reduction : 0-5, 5 level

13.5

Dynamic rate: 30-180, Step 5

13.6

Line density : low-middle-high , 3 level

13.7

Frame Correlation : 0-4 ,  4 level

13.8

False-color : 0-67, 67 level

13.9

Image style : Soft-Comparison, 2 level

13.10

Noise reduction : 0-5, 5 level

13.11

Edge Enhancement : 0-5 , 5 level

13.12

Sound power: 2-10, 8 level

13.13

Grey map : 0-67, 67 level

☆14

Trapezoidal imaging

14.1

Probe support: linear probe

14.2

Adjustment of B mode parameters is switchable

14.3

Deflection angel: 8 level

14.4

Speckle reduction : 0-5, 5 level

14.5

Dynamic rate: 30-180, Step 5

14.6

Line density : low-middle-high , 3 level

14.7

Frame Correlation : 0-4 ,  4 level

14.8

False-color : 0-67, 67 level

14.9

Image style: Soft-Comparison, 2 level

14.10

Noise reduction : 0-5, 5 level

14.11

Edge Enhancement : 0-5 , 5 level

14.12

Sound power : 2-10 , 8 level

14.13

Grey map : 0-67 ,  67 level

14.14

Space Synthesis : 0-2, 2 level

☆15

Freehand 3D imaging

15.1

Support probe : convex probe, linear probe

15.2

Display model: 4 pictures

15.3

Image Rotation X/Y/Z Axis

15.4

Multi-slice Visibility

16

Real-time 4D imaging

16.1

Support probe: 4D volume probe

16.2

Adjustment of B mode parameters is switchable

16.3

Gain : 0-100 , Step 2

16.4

Display model : one image、two images、four images

16.5

Image Rotation : X/Y/Z Axis

16.6

Multi-slice Visibility

16.7

Light&Shade inversion

16.8

Smooth : 0-4, 4 level

16.9

Threshold level : 0-129, Step 3

16.10

Transparency : 1-509 , Step 10

16.11

Render type : 4 kinds , Surface、maximum、minimum、perspective

17

Extended Imaging

17.1

Gain : 0-100 , Step 2

17.2

TGC : 8 segment adjustable

17.3

Maximum focus point : ≥7, which can be moved throughout the whole process.

17.4

Speckle reduction : 0-5 , 5 level

17.5

Space Compound : 0-2 , 2 level ( Linear probe: 3 level , don’t support cardiac probe )

17.6

Dynamic range : 30-180 , 35 level , Step 5

17.7

Line density : Low、Middle、High , 3 level

17.8

Frame correlation : 0-4,4 level

17.9

Noise reduction : 0-5 , 5 level

17.10

Edge enhancement : 0-5 , 5 level

17.11

Sound power : 2-10, 9 level

17.12

Grey map : 0-67, 67 level

17.13

False color : 0-67 , 67 level

17.14

Image style : Soft-Comparison, 2 level

17.15

Extended level: Maximum 72 level

Convex probe : 9 level

Trans-vaginal probe : 72 level

Micro-convex probe : 29 level

Cardiac probe : 40 level

4D Volume probe : 17 level

 PS : 

The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted

 PS : 

When the probe scan range reaches the maximum, the space synthesized is 0.

18

Measurement and analysis function:

18.1

General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle, etc.

18.2

Cardiac : Automatic spectrum envelope、LV、Main Pulmonary artery diameter、RVEDd、RVEDs、LVM、LAV、HR、MVF、AO、AR、LVOT、TVF、Pulmonic valve、Pulmonary vein、RV、Doppler fetal heart sound、LVET、LVM、LVMI、AV, etc.

18.3

Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall)

18.4

OB : Fetal routine、AFI、TW、GS、CRl、OFD、HL、ulna、NT、Fibula、Nbonel、Radial、Tibia

18.5

GYN : uterus、cervix、corpus uteri/cervix uterus、left ovarian vein、right ovarian vein、dominant follicle、intima thickness , etc.

18.6

Urology: prostate、residual urine、left kidney、right kidney、left suprarenal vein、right suprarenal、left testis、right testis、left seminal vesicle、right seminal vesicle , etc.

18.7

Abdomen : liver、CHD、partal vein diameter、cholecyst、CBD、pancreas、spleen、Internal diameter of abdominal aorta、kidney , etc.

18.8

Small parts : Thyroid, etc.

18.9

Software package : Measurement package、Software package、Medical records management software package , etc.

19 

Graphic and text management system

19.1

Host build in 2 hard disk ( SSD 120+1T )  , Start fast and stable

19.2

Movie playback : ≥1200 frames

19.3

Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.

19.4

Type of report is 16

19.5

One key fast report graphic and text management

20

Interface

20.1

USB interface:  2 

HDMI interface:  1

RJ-45 interface: 1

Grounding wire interface: 1

 21

Configuration

21.1

Portable type full digital color Doppler ultrasound diagnostic system

21.2

Probe: convex array probe (standard), linear probe (optional), 

Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional)

21.3

≥13 quick-adjusting knobs

22

Technology, after-sales service, and other requirements

22.1

After acceptance, the warranty is free for two years ( Provide manufacturer warranty certificate )

22.2

The manufacturer has ISO13485 certification and EU CE certification.

Packing Details:

Metal case  size: 71*43*55cm
N.W. 20kgs
G.W. 25kgs

No reviews found

Not satisfied with the unit price? Get a free quote on bulk quantities within 8 hours.