Z-Arm Digital Radiography Equipment AG-Staray 5000

Write a review
AG-Staray 5000 Z-Arm
In stock
Price: click login to view
Get a quotation upon your custom quantity

- Radiography Machine Manufacturer

Flat Panel Detector

Mechanical structure: scythe arm(type Z)

High Voltage Generator

X-ray Tube

Filter grid

LED Collimator

  • Video gallery

Z-arm digital radiographic equipment  AG-Staray 5000

This X-ray device uses high-energy X-rays to penetrate the body and create images of internal organs and bones.The resulting images can be used to diagnose and treat medical conditions. It is designed as a Z-Arm, making it easier and more convenient to move and operate.

standard

1flat panel detector
1.1Amorphous silicon flat panel detector
1.2Effective pixels: 90,000
1.3Pixel matrix: 3071*3071 pixels
1.4Quantization depth: 16 bits
1.5Effective area: 17"*17"
1.6Pixel size: 140μm
1.7Spatial resolution: 3.7 L/mm
1.8Imaging time:7.6s 
2Mechanical structure: scythe arm(type Z) 
2.1Stand weight: 210kg (the whole machine weight ≤ 288kg) 
2.2Vertical range(scythe arm): 600mm ~ 1600mm(±5%) 
2.3Rotation range of the scythe arm: -45°~ +135°(±2°) 
2.4SID (vertical and horizontal) can be adjusted electronically, the range: 1000mm~1800mm(±5%) 
2.5Rotation range of the tube assembly :-15°~+15°(±2°) 
2.6Rotation range of the detector:-45°~+45°(±2°) 
2.7One-key flat bed position, one-key chest radiograph position 
2.89.5 "LCD touch screen 
2.9Minimum height of the equipment room:2.4m 
2.10The tube and detector move synchronously to maintain the balance of the stand 
2.11The detector end can independently control the movement of the stand 
3High Voltage Generator 
3.1High voltage generator smart network voltage real-time monitoring system(smart monitor) 
3.2Power: 50kW 
3.3kV range: 40kV-150kV 
3.4mA range: 10mA-630mA 
3.5mAs range: 0.1mAs-630mAs 
3.6Time range for loading: 1ms - 6300ms 
3.7Inverter frequency: 60-200kHz 
4X-ray Tube 
4.1Focus size:0.6mm/1.2mm 
4.2Focus power: small focus: 20kW large focus: 50kW 
4.3Maximum heat capacity:300kHU 
4.4Maximum peak voltage:150kV 
5Filter grid 
5.1Size: 18 inch×18 inch 
5.2Ratio:≥10:1 
5.3Electrical mode 
6LED Collimator 
6.1The time limit of indicator:30±3s 
6.2Radiation field light: 150W, 24VAC 
6.3Radiation leakage:≤0.54mGy/h 
7Table 
7.1Table height: 70cm (±5cm) 
7.2Table length: 200cm (±5cm) 
7.3Table width: 70cm (±5cm) 
7.4Load bearing: 135kg 
8.2Software function(patient management) 
8.2.1Remote direct access to patient information in RIS with worklist protocol;
Manually create the patient examination information;
8.2.2Emergency quick registration;
8.2.3Simple, advanced, or custom data query methods; 
8.2.4Inquiry and management of historical image data;
8.2.5The image CD burning in Dicom standard ,can be viewed on any standard image workstation;
8.2.6Detection of disk space, automatic cleaning of old check data; 
8.2.7Dicom transmission of image and seamless connection with PACS;
8.2.8Support diagram text report, carry report library;
8.2.9Print patient reports and exposure times can be displayed in the list of patients; The original image is easy to view. 
8.3Software function(software direct exposure control) 
8.3.1Support customization for dose template;
8.3.2Selection part and position template, automatically bring out the matching dose; Selection shape of the patient, automatically select the matching dose and adjust to the dose online;
8.3.3Control the size of focus;
8.3.4Display generator's status transparent;
8.3.5Refusal and acceptance of images;
8.3.6Support automatic sending of images. 
8.4Software function(image processing) 
8.4.1Supports dual or multi-screen images display;
8.4.2Manually/automatically/preset window width and window level, partial window width and window level; 
8.4.3Operation positive and negative of image, flip image, rotation image, scaling image, and roaming;
8.4.4Automatic or manual addition of image information;
8.4.5Line, angle, rectangle, ellipse, polygon, and other measuring tools; 
8.4.6Balance tissue,enhancement contrast,optimization dose;
8.4.7Enhancement edge: automatic recognition and analysis of images, enhance edge sharpness. 
8.4.8Preview the post-processing image 1:1: the doctors make a more intuitive diagnosis in image optimization;
8.4.9CAD View: just click the mouse, and doctors can see the details of the image more clearly so that doctors can make a more accurate diagnosis. 
8.5Software function(film printing) 
8.5.1Set film properties, image layout, and printing mode;
8.5.2Typeset quickly by manual/automatic ;
8.5.3Select any camera within the network;
8.5.4Customization of patient information and display location; Support for queue management; 
8.5.5Support for setting print priority. 
9Optional functions 
9.1AEC -- Automatic exposure control technology;
Accurate and efficient dose management;
Improve the image quality;
Easy Operation. 
9.2Image stitching:
Seamless stitching, smooth and natural. 
9.3EE-PACS:
A very powerful PACS system, using B/S architectural design and based on international DICOM and HL7standards. It is designed and optimized for high workflow efficiency and productivity, as well as friendly and intuitive user interfaces. It provides a rich set of modules to meet your daily needs.  