AG-AM006 Anesthesia Machine
AG-AM006 Anesthesia Machine
Specification
Ventilation modes: | 1 Manual 2 (V-CMV)PPV 3 (P-CMV)PCV 4 (P-S1MV)(V-S1MV) 5 PSV 6 PRVC |
Monitoring Parameters: | 1 Tidal Volume 2 Minute Volume 3 PEEP 4 Airway pressure 5 Respiratory frequency 6 I: E 7 Resistance 8 Compliance 9 Oxygen concentration |
Waveform: | 1 P-T 2 F-T 3 V-T 4 Lung function loop 5 ETCO2 waveform |
Function: | 1 AG monitoring(OPTIONAL) 2 ETCO2 3 AGSS(OPTIONAL) 4 Electronic monitoring gas source pressure 5 Mechanical/Electronic rapid oxygen 6 ACGO 7 Assist air supply/oxygen supply 8 Built-in battery |
Adjusting Parameter | Tidal Volume:10mL~1500ml Inspiration pressure: 1cmH2O; Pressure support: 3cmH2O~50cmH2O; Pressure limit: 10cmH2O~100cmH2O; PEEP: 0cmH2O~30cmH2O; Respiration frequency: 4bpm~100bpm; Inspiration apnea: OFF, 5%~60%; I:E: 4:1~1:10; Inspiration time: 0.2s~5s; Trigger: 5%~95%; SIMV frequency: 4bpm~60bpm; Pressure trigger: -1cmH2O~-20cmH2O; Flow trigger: 0.3 L/min,1L/min~15L/min; Rise time:0s~2s; |
Monitoring parameter | Tidal volume:0mL~2500mL;
Minute volume:0L/min~100L/min; Respiration frequency:0bpm~120bpm; Oxygen concentration:15%~100%(V/V) Airway pressure:-20cmH2O~100cmH2O; Inspiration platform pressure:0cmH2O~100cmH2O; PEEP:0cmH2O~70cmH2O; I:E:4:1~1:10; Resistance:0 cmH2O/(L/s)~250 cmH2O/(L/s); Compliance:0 ml/cmH2O~250 ml/cmH2O; |
AG(optional) | CO2: 0%~15%(V/V);
N2O: 0%~100%(V/V); Enflurane、Isoflurane: 0%~8%(V/V); Sevoflurane: 0%~10%(V/V); |
Alarm | VT UPPER LIMIT: 5mL~2000mL;
VT LOWER LIMIT: 0mL~1595mL; MV upper limit: 0.1L/min~100L/min; MV lower limit: 0.0L/min~99.9L/min; Respiration frequency upper limit: 2bpm~100bpm; Respiration frequency lower limit: 0bpm~98 bpm; FIO2 upper limit: 20%~100%; FIO2 lower limit: 18%~98%; Airway pressure upper limit: 2cmH2O~100cmH2O; Airway pressure lower limit: 0cmH2O~98cmH2O; Apnea: 20s~40s Oxygen concentration never lower than 25% when N2O start |
Testing | Automatic leakage compensation testing.
Patient circuit leakage compensation and automatic compliance compensation. Patient monitor and AG monitor can be equipped. Manual ventilator, mechanical ventilation and standby. Waveform: P-T, F-T, V-T, Lung function loop, ETCO2, Anesthesia gas, oxygen concentration, N2O concentration. Self-testing visible Alarming visible ACGO function |
Battery working | There are two batteries inside, use one of them can last long for no less than 60 mins, when using two, it can last long for no less than 120 mins. |