AG-1100 Animal Medical Diagnostic X-ray System
AG-1100 Animal Medical Diagnostic X-ray System
Specification:
1. Basic parameters
1.1 X-ray source system 1.1.1 High voltage generator | Output power: 4.5kW
Inverter frequency: 40kHz Minimum exposure time: 10ms Radiography voltage: 40kV~120Kv Radiography current: 25mA~100mA Radiography mAs: 1.0mAs~180mAs |
1.1.2 X-ray Tube | Focus Size: 0.3/1.5
Anode angle: 15° Anode thermal capacity: 35kJ Tube thermal capacity: 500kJ With Anode filter: Yes |
1.1.3 Beam limiter | Inherent filter value: 1.2mmAl
Additional filter value: 1.0mmAl、2.0mmAl Maximum X-ray irradiation area: 1M maximum irradiation 17×17 |
1.2.3 Radiography table | Table manufacturer: Perlove
Whether the table can float in four directions: Yes Longitudinal floating distance of tale: 480mm Horizontal floating distance of table: 220mm |
1.2.4 Wired exposure hand brake | Whether equipped with hand brake:yes Whether the two-speed handbrake exposure form:yes |
1.2.5 Wireless remote exposure control | Whether equipped with a wireless remote exposer:yes Remote control distance:10m |
1.2.6 Working conditions | Power Voltage: 220V±22V
Power frequency: 50Hz±1Hz Internal resistance: Less than 1Ω |
1.3 Imaging system 1.3.1 Flat panel detector | |
Wired or wireless | Wired |
Detector types | Amorphous silicon |
Scintillator types | CSI |
Panel size | 430mm*430mm |
Spatial resolution | 3.6lp/mm |
Pixel matrix | 3072x3072 |
Output greyscale | 16bit |
Pixel size | 154μm |
1.4 Image acquisition workstation 1.4.1 Image acquisition and processing system software | 1. Registration function: Registration and maintenance, medical record inquiry, modification, worklist 2. Acquisition function: Exposure parameter adjustment, exposure control, cropping, marking 3. Processing function: Vertical mirroring, horizontal mirroring, window width window position, single window, double window, shift, zoom, negative image, measurement 5. Reporting function: Reports writing and printing 6. Printing function: Film printing 7. Dicom function: Compliant with Dicom 3.0 standard |
2. System configuration 2.1 Standard configuration | X-ray tube----------------------------1 set
MainbodyVET1100-------------------1 set Workstation 24" computer---------1 set 17*17M FPD--------------------------1 set Workstation software--------------1 set |
3. Description of performance characteristics 3.1 Description of the performance characteristics | 1. Adopt high-frequency inverter technology, good ray quality, stable and reliable, good image clarity and contrast. 2. Using kV closed-loop control technology,mAs digital closed-loop control technology, microcomputer real-time control, to ensure the accuracy and extremely high repeatability of the dose. 3. Adopt kV, mAs to adjust the photography parameters, true color screen display, with multiple protection functions such as tube voltage over-voltage, tube current over-current, output overload, X-ray tube heat capacity, etc.. 4. With several filming procedures, which can be modified and saved by the user. 5. Low dose, low amplitude radiation, safer. High-quality combined X-ray generator, greatly reducing the radiation, environmental protection and operator safety. 6. With automatic fault protection device and fault alarm display. 7. The system automatically saves the parameters after power failure to ensure that the parameters are not lost. 8. The use of hand control, remote control dual control photography function, wireless remote exposure control is not blocked by obstacles, easy to operate. 9. Support barcode scanning gun for patient information collection. 10. With professional veterinary image acquisition software. 11. Specialized operation process, support DICOM 3.0 standard, accurate image processing; support report output. |