Portable Patient Monitor LCX-PM10A

Write a review
LCX-PM10A*
Out of stock
Price: click login to view
Get a quotation upon your custom quantity
Portable Patient Monitor LCX-PM10A Specification Features -• 10.1 inch high-resolution color FT display • Lightweight and portable design suitable for Ambulance, Emergency Transport • Three Working Modes: Monitoring, Surgery, and Diagnosis. • Simple and friendly...

Minimum quantity for "Portable Patient Monitor LCX-PM10A" is 1.

Port: Shanghai,China
Payment
Share to

Portable Patient Monitor LCX-PM10A

Specification

Features

-• 10.1 inch high-resolution color FT display

• Lightweight and portable design suitable for Ambulance,

Emergency Transport

• Three Working Modes: Monitoring, Surgery, and Diagnosis.

• Simple and friendly operating display interface.

-• Multi-display modes suitable for different applications:

Standard Interface, Large font, ECG Standard Full Display, OXY, Trend Table, BP Trend.

• Built-in high capacity battery up to 3 hours of continuous work 

Technique Specification

ECG

• Lead Mode: 5 Leads (I, Il, III, AVR, AVL,AVF, V)

-• Gain: 2.5mm/mV, 5.0mm/mV. 10mm/mV. 20mm/mV

• Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)

Resolution: 1 BPM

Accuracy: +1%

Sensitivity >200 V(Peak to peak)

-• ST measurement range: -2.0 ~ +2.0 mV

Accuracy: -0.8mV~+0.8mV: ‡0.02mV or ‡10%, which is greater

Other Range: unspecified

• Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s

• Bandwidth:

Diagnostic: 0.05~130 Hz

Monitor:0.5~40 HZ

Surgery:1~20 HZ

 SP02

• Measuring Range: 0 ~ 100 %

• Resolution: 1%

• Accuracy: 70% ~ 100% (‡2 %)

• Pulse Rate: 20-250 BPM

Resolution: 1 BPM

Accuracy: ±3 BPM

Optinal Parameters:

• Central monitoring system

• Dual IBP

• Etco2

• 12-lead ECG:

• Nellcor Sp02;

• Sun Tech NIBP.

 NIBP

Method: Oscillometry

Measure mode: Manual, Auto. STAT

Unit: mmHg, kPa

Measure and alarm range:

Adult Mode

SYS 40 ~ 280 mmHg

DIA 10 ~ 225 mmHg

MEAN 20 ~ 240 mmHg

Pediatric Mode

SYS 40 ~ 220 mmHg

DIA 10 ~ 160 mmHg

MEAN 20 ~ 170 mmHg

Neonatal Mode

SYS 40 ~ 135 mmHg

DIA 10 ~ 100 mmHg

MEAN 20 ~ 110 mmHg

Resolution: 1mmHg

Accuracy: ±5mmHg

 TEMP

• Measure and Alarm Range: 0 ~ 50 C

• Resolution: 0.1C

• Accuracy: ‡0.1C

 Standard Parameters:

ECG. RESP. TEMP. NIBP. SPO2. PR

 RESP

• Method: Impedance between RA-LL or RALA

• Measurement Range:

Adult: 10 ~ 120 BrPM

Neonatal / Pediatric: 7 ~ 150 BrPM

• Resolution: 1 BrPM

Accuracy: ±2 BrPM

Packing:

• Single package size: 34.7*20.7*27.7cm

• Single gross weight: 2.8 KG

• 6 units per carton, package size:

• 65*36.2*59cm, total gross weight 18 KG

NO

ITEM

QTY

1

Main Unit

1

2

5-lead ECG cable

1

3

Disposable ECG Electrode

5

4

Adult Spo2 probe

1

5

Adult NIBP cuff

1

6

NIP extension tube

1

7

Temperature probe

1

8

Power Cable

1

9

User Manual

1

10

Fuse

3


No reviews found