Multi-Parameter Monitor LCX-PM12D Specification Features 1. 12.1 inch color display with 800*600 resolution. 2. Three Working Modes: Monitoring,Surgery and Diagnosis. 3....

Minimum quantity for "Multi-Parameter Monitor LCX-PM12D" is 1.

Port: Shanghai,China
Payment
Share to

Multi-Parameter Monitor LCX-PM12D

Specification

Features

1. 12.1 inch color display with 800*600 resolution.

2. Three Working Modes: Monitoring,Surgery and Diagnosis.

3. Simple and friendly operating display interface.

4. Multi-display modes suitable for different applications:

Standard Interface,Large font,ECG Standard Full Display,OXY,Trend Table,

BP Trend.

5.Built-in rechargeable Lithium battery up to 3 hours of continuous work

6.VGA output for external display. 

Technique Specification

ECG

1. Lead Mode:5 Leads (I,Il,IlI,AVR,AVL,AVF,V)

2. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)

Resolution: 1 BPM

Accuracy:±1%

Sensitivity>200 uV(Peak to peak)

4. ST measurement range:-2.0~+2.0 mV

Accuracy:-0.8mV~+0.8mV:±0.02mV or±10%, which is greater

Other Range:unspecified

5. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s

6. Bandwidth:

Diagnostic: 0.05~130 Hz

Monitor: 0.5~40Hz

Surgery: 1~20 Hz

SPO2

1. Measuring Range:0~100%  

2. Resolution:1%

3. Accuracy:70%~100%(±2%)

4. Pulse Rate:20-250 BPME

5. Resolution:1 BPM

6. Accuracy:±3 BPM

Optional Parameters

1. Recorder(Printer)

2. Central monitoring system

3. Dual IBP

4.Etco2

5.12-lead ECG;

6. Nellcor SpO2;

7. Sun Tech NIBP.

NIBP

1. Method: Oscillometry

2. Measure mode: Manual, Auto, STAT

3. Unit: mmHg,kPa

4. Measure and Alarm Range:

5. Adult Mode

SYS 40~280 mmHg

DIA 10~225 mmHg

MEAN 20~240 mmHg 

6.Pediatric Mode

SYS 40~220 mmHg

DIA 10~160 mmHg

MEAN 20~170 mmHg 

7.Neonatal Mode

SYS 40~135 mmHg

DIA  10~100 mmHg

MEAN 20~110 mmHg

8.Resolution:1mmHg

9.Accuracy:±5mmHg 

Temp

1.Measure and Alarm Range: 0~50 C

2.Resolution:0.1C

3.Accuracy:±0.1C 

Standard Parameters:

ECG,RESP,TEMP,NIBP,SPO2,PR

RESP

1. Method:Impedance between RA-LL or RALA

2. Measurement Range:Adult:10~120 BrPM

Neonatal/Pediatric: 7~150 BrPM

3. Resolution:1 BrPM

4. Accuracy:±2 BrPM

5. 

Standard Confiduration:

Item

Qty

Main unit

1

5-lead ECG cable

1

Disposable ECG Electrode

5

Adult Spo2 probe

1

Adult NIBP cuff

1

NIBP extension tube

1

Temperature probe

1

Power Cable

1

User Manual

1

Fuse

3

Packing:

1. Single package size: 37*28*36cm

2. Single gross weight: 4.5KG

3. 4 unit per carton, package size:58*39*75cm, total gross weight: 20 KG

No reviews found