Multi-Parameter Patient Monitor LCX-PM12F

Write a review
LCX-PM12F*
Out of stock
Price: click login to view
Get a quotation upon your custom quantity
  • Unique accessory management cabinet
  • 12.1-inch high-resolution color TFT display
  • USB interfaces
  • 3 Working Modes: Monitoring, Surgery, and Diagnosis

Minimum quantity for "Multi-Parameter Patient Monitor LCX-PM12F" is 1.

Port: Shanghai,China
Payment
Share to

Multi-Parameter Patient Monitor LCX-PM12F

Function

1. Unique accessory management cabinet

2. 12.1-inch high-resolution color TFT display

3. USB interfaces support easy software upgrades and data transfer

4. Three Working Modes: Monitoring, Surgery, and Diagnosis.

5. Simple and friendly operating display interface.

6. Multi-display modes suitable for different applications:

7. Standard Interface, Large font, ECG Standard Full Display, OXY, Trend Table, BP Trend.

8. Built-in high-capacity battery for up to 3 hours of continuous work

9. VGA output for external display 

Specification

ECG

Lead Mode: 5 Leads (I, Il, III, AVR, AVL,AVF, V)

Gain: 2.5mm/mV. 5.0mm/mV. 10mm/mV. 20mm/mV

Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)

Resolution: 1 BPM

Accuracy: ±1%

Sensitivity: >200 uV(Peak to peak)

ST measurement range: -2.0 ~ +2.0 mV

Accuracy: -0.8mV~+0.8mV: +0.02mV or +10%, which is greater

Other Range: unspecified

Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s

Bandwidth:

Diagnostic: 0.05~130 Hz

Monitor:0.5~40 HZ

Surgery:1~20 HZ

SPO2

Optinal Parameters:

• Measuring Range: 0 ~ 100 %; Resolution: 1%

• Accuracy: 70% ~ 100% (‡2 %)

• Pulse Rate: 20-250 BPM; Resolution: 1 BPM; Accuracy: +3 BPM

• Recorder ( Printer)

• Central monitoring system

-• Dual IBP

• Etco2

• 12-lead ECG:

• Nellcor Sp02;

• Sun Tech NIBP.

NIBP

Method: Oscillometry

• Measure mode: Manual, Auto, STAT

• Unit: mmHg, kPa

• Measure and alarm range: 

• Adult Mode

SYS 40 ~ 280 mmHg

DIA 10 ~ 225 mmHg

MEAN 20 ~ 240 mmHg

• Pediatric Mode

SYS 40 ~ 220 mmHg

DIA 10 ~ 160 mmHg

MEAN 20 ~ 170 mmHg

• Neonatal Mode

SYS 40 ~ 135 mmHg

DIA 0 ~ 100 mmHg

MEAN 20 ~ 110 mmHg

• Resolution: 1mmHg

• Accuracy: ‡5mmHg 

TEMP

• Measure and Alarm Range: 0 ~ 50℃

• Resolution: 0.1℃

• Accuracy: +0.1℃

Standard Parameters:

• ECG. RESP, TEMP, NIBP, SPO2, PR 

RESP

• Method: Impedance between RA-LL or RALA

• Measurement Range:

Adult: 10 ~ 120 BrPM

Neonatal / Pediatric: 7 ~ 150 BrPM

• Resolution: 1 BrPM

• Accuracy: ±2 BrPM

Standard Configuration:

Main Unit* 1

5-lead ECG cable* 1

Disposable ECG Electrode* 5

Adult Spo2 probe* 1

Adult NIBP cuff* 1

NIBP extension tube* 1

Temperature probe* 1

Power Cable* 1

User Manual* 1

Fuse* 3

Packing:

•Single package size: 37*28*36cm

• Single gross weight: 4KG

• 4 units per carton, package size: 58*39*75cm, total gross weight 18KG