MWCPR-1D-B2 Auto-CPR Device

In stock
Price: click login to view
Get a quotation upon your custom quantity
MWCPR-1D-B2 Auto-CPR Device Auto-CPR Device Parameter 1.working principle:motor-driven and Electric control; 2.Pressing depth:30mm~70mm continuously adjustable, each adjustment 5mm; 3.Pressing frequency:100 times/minute, 110 times/minute, 120 times/minute continuously adjustable; 4.Press...
+

Minimum quantity for "MWCPR-1D-B2 Auto-CPR Device" is 1.

Port: Shanghai,China
Payment
Share to

MWCPR-1D-B2 Auto-CPR Device

Auto-CPR Device Parameter

1.working principle:motor-driven and Electric control;

2.Pressing depth:30mm~70mm continuously adjustable, each adjustment 5mm;

3.Pressing frequency:100 times/minute, 110 times/minute, 120 times/minute continuously adjustable;

4.Press the ventilation ratio: 30: 2,15: 2, separete continuously press three operation modes can be switched;

5.Progressive compression function can reduce the risk of fracture. The software of the device has the function of monitoring the pressing depth;

6.Press release ratio: 1:1 (50%: 50%);

7.Prompt function: power display, low voltage alarm, start pause function, with press, ventilation status indicator light prompt function;

8.Safety prompt mode: when the pressing depth is adjusted from 50mm to 55mm, the function of safety confirmation is required;

9.The default state of power on: the pressure ventilation ratio is 30:2, the pressing depth is 30mm, the pressing frequency is 100 times / min, and the blowing frequency is 20 times / min

10.Equipment human-computer interaction: one key into the guide mode, key indicators standardization, improve operation efficiency

11.Chest thickness measurement indication function, vertical adjustment height: 150 mm, tolerance ± 5 mm;

12.Single arm vertical classic bionics press structure, 360 degree rotation of the host can make the chest open, which is convenient for defibrillation and other equipment to operate at the same time;

13.The control panel is located above the patient to reduce the infection caused by blood and body fluid of trauma patients and avoid the risk of infection for operators;

14.Open cantilever type steel support device: according to the difference of patient's body shape and operating environment, the host can be adjusted up and down and swing left and right, and the pressing head can be quickly positioned with the patient's chest. Tighten the locking handle to ensure that the pressing head is always close to the chest during pressing.

No reviews found