Venus Critical Care Patient Monitor For ICU,CCU,NICU

Write a review
Venus
In stock
Price: click login to view
Get a quotation upon your custom quantity
Venus Critical Care Patient Monitor For ICU,CCU,NICU Specification Configuration 5-lead ECG, SpO2, NIBP, TEMP, Resp, PR; Touchscreen, HDMI, Li-ion battery   Optional 12-Lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-gas, BIS, NMT; Thermal Recorder,...
+

Minimum quantity for "Venus Critical Care Patient Monitor For ICU,CCU,NICU" is 1.

Port: Shanghai,China
Payment
Share to

Venus Critical Care Patient Monitor For ICU,CCU,NICU

Specification


Configuration

5-lead ECG, SpO2, NIBP, TEMP, Resp, PR; Touchscreen, HDMI, Li-ion battery

 

Optional

12-Lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-gas, BIS, NMT;

Thermal Recorder, Wired/Wireless CMS, 4G module

 

· 15.6” High resulotion TFT LCD Touch screen

· 10 waveform display,up to 12-lead ECG analysis

· Powerful calculation(Hemodynamic,Dose,Oxygenation,Ventilation)

· MEWS(Modified Early Warning Score)

· Pacemaker detection

· ST & arrhythmia analysis(26 types)

· SpO2 support PVI and PI,low perfusion 0.2%

· Night mode, standby mode, venipucture mode

· Trolley/wall mount braket solutions

· Support BIS module, NMT module

· Wired/Wireless/4G connection, support HL7 protocol to HIS

· SpO2 pulse-tone modulation (Pitch Tone)

· VGA/HDMI support external display

· Graphical & tabular trend review

· Rechargeable Lithium-ion Battery

· 72 hours full disclosure wave review for each patient

 

Specifications

Physical Specification

Display

15.6” TFT Touch screen

Resolution: 1366 x 768

Number of traces: 10, up to 12 ECG waveforms

Dimension: 398×302×183mm(W×H×D)

Weight: < 7 kg under standard configuration

LAN: 1 standard RJ45 port

WLAN:IEEE 802.11b/g/n

USB: 2 USB connectors

HDMI: 1 HDMI monitor connnector

Output:1 connector for Nurse call,Defib Sync Analog Output

 

ECG

Lead type :3-lead,5-lead,12-lead(optional)

ECG waveform:2 channels,7 channels, 12 channels

Display sensitivity(wave gain):

1.25mm/mV(×0.125), 2.5mm/mV (×0.25), 5mm/mV (×0.5),

10mm/mV (×1.0), 20mm/mV (×2.0),40mm/mV (×4.0),

Auto

Wave sweep speed:

3.125mm/s, 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

Bandwidth

 Diagnostic mode: 0.05Hz~150Hz

 Monitor mode: 0.5Hz~40Hz

 Surgery mode: 0.5Hz~25Hz

 Strong filter mode: 5Hz~25Hz

CMRR>100dB

Notch: 50/60Hz notch filter can be set to on or off

Differential input impedance>5MΩ

Electrode polarization voltage range: ±400mV

HR range: 15 - 350 bpm

Baseline recovery time<3s after defibrillation (in monitor

and surgery mode)

Calibration signal:1mV (peak - peak), accuracy ±3%

 

RESP

Measurement method : Thoracic electrical bioimpedance

Measuring lead: Lead I, II

Wave gain: ×0.25, ×0.5, ×1, ×2

Respiratory impedance range: 0.5-5Ω

Respiration range: 0 - 150bpm

Baseline impedance: 500-4000Ω

Gain: 10 grades

Scan speed: 3.125mm/s, 6.25mm/s, 12.5 mm/s, 25mm/s

 

TEMP

Accuracy:±0.1℃ or ±0.2℃ °F(without probe)

Measurement range: 5~50℃ (41~122°F)

Channel:Two channels

Resolution: 0.1℃

 

SpO2

Measurement range : 0-100%

Parameter monitoring: Perfusion Index(PI)

 Pleth Variability Index(PVI)

Resolution: 1%

Accuracy: ±2% or ±2bpm

Refreshing Rate: 1s

Pleth wave speed: 3.125mm/s, 6.25mm/s, 12.5 mm/s, 25mm/s

 

Masimo SET® SpO2(Optional)

Measurement range : 0-100%

Resolution: 1%

Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion,

 low perfusion);

 ±3%(70-100%, Neonate,non-motion);

 ±3%(70-100%, motion);

 0-69%,unspecified

Refreshing Rate: 1s

 

Pulse Rate

Range: 30~300 bpm

Resolution: 1bpm

Accuracy: ±2bpm (non-motion)

 ±5bpm (motion)

Refreshing rate: 1s

 

NIBP

Measurement method : Automatic oscillometric method

Operating mode:Manual, automatic, continuous

Measurement unit: mmHg/kPa selectable

Typical measurement time: 20~40s

Measurement type: Systolic, Diastolic,Mean

Measurement range (mmHg)

Range of Systolic pressure: Adult 40-280

 Pediatric 40-200

 Neonatal 40-135

Range of Diastolic pressure: Adult 10-210

 Pediatric 10-150

 Neonatal 10-95

Range of Mean pressure: Adult 20-230

 Pediatric 20-165

 Neonatal 20-105

Measurement accuracy

Maximum average error: ±5mmHg

Maximum standard deviation: 8mmHg

Resolution: 1mmHg

Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes

Overpressure protection: Software and hardware,

 double safety protection

Cuff pressure range: 0-300mmHg

 

IBP(Optional)

Channel:2-channel or 4-channel

ART: 0 to 300 mmHg

PA: -6 to 120 mmHg

CVP/RAP/LAP/ICP : -10 to 40 mmHg

Measurement range: P1/P2 -50 to 300 mmHg

Resolution:1mmHg

Accuracy:

±2% or ±1mmHg, whichever is greater(without sensor)

Sensitivity: 5uV/mmHg/V

Impedance range: 300 to 3000Ω

 

C.O.(Optional)

Method: Thermodilution

Range: C.O.: 0.2 to 20 L/min

 TB: 23 to 45 ℃

 T1: -1 to 27℃

Accuracy:C.O.:±5% or ±0.1L/min,whichever is greater

TB,T1:±0.5℃ (without sensor)

 

Northern Mainstream CO2(Optional)

Measurement range: 0-19.7%,150mmHg, or 0-20kPa

Resolution: 0.1mmHg

Measurement accuracy

 0 - 40 mmHg: ± 2 mmHg

 41 - 70 mmHg: ± 5% of reading

 71 - 100 mmHg: ± 8% of reading

 101 - 150 mmHg: ± 10% of reading

Respiration rate: 3-150 bpm

Respiration rate accuracy: 1% ±1bpm

Warm-up time: 97% within 8s, full accuracy within 20s

 

Northern Sidetream CO2(Optional)

Measurement rage: 0-20%(0-150mmHg)

Accuracy: < 5.0% CO 2: ± 2 mmHg

 > 5.0% CO 2: < 6% of reading

Respiration rate: 2 ~ 150 BPM

Respiration rate accuracy: 1% ±1BPM

Warm-up time: 97% within 45s, full accuracy within 10 min

Rise times(t10-90%): About 100ms, when flow is 100 ml/min,

adult water trap,1.5m sampling tube

Delay time: <3sec when flow is 100 ml/min, adult water trap,

1.5m sampling tube

 

Recorder (Optional)

Built-in, Thermal dot array

Horizontal resolution :16 dots/mm (25 mm/s paper speed)

Vertical resolution:8 dots/mm

Paper speed:12.5mm/s, 25 mm/s, 50 mm/s

Number of waveform channels: 3

 

Masimo ISATM Sidestream CO2 (Optional)

Warm-up time: Full accuracy within 10 seconds

Sampling flow rate: 50ml/min(+/-10/min)

Measurement Range: 0 -25%

Accuracy: 0~15% (±0.2% of the reading)

 15~25%, unspecified

Rise time: 200ms,typical at 50ml/min flow rate

Total response time:

within 3 seconds (with 2 m Momoline sampling line)

AWRR Range: 0-150bpm

AWRR Accuracy:±1 breath

 

Masimo IRMATM Mainstream CO2 (Optional)

Measurement Range: 0 -25%

Accuracy: 0~15% (±0.2% of the reading)

 15~25%, unspecified

Warm-up time: Full accuracy within 10 seconds

AWRR Range: 0-150bpm

AWRR Accuracy:±1 breath

 

Masimo Multi-gas ISA OR+/IRMA AX+ CO2 (optional)

Gas:CO2,N2O,HAL,ISO,ENF,SEV,DES with automatic

identification

Warm-up time: Full accuracy within 20 seconds for IRMA

AX+ CO2 Accuracy: 0-10%:±(0.2%+2% of the reading)

 0-15%:±(0.3%+2% of the reading)

N2O Accuracy: 0-100%:±(2%+2% of the reading)

HAL,ISO,ENF: 0-8%:±(0.15%+5% of the reading)

SEV:0-10%: ±(0.15%+5% of the reading)

DES:0-22%: ±(0.15%+5% of the reading)

Agent identification time:<20s(typical<10s)

AWRR range: 0-150bpm

AWRR accuracy: +/-1bpm

Apnea time: 20~60s

 

Aspect BISx module(Optional)

Parameter Measurement:

BC: 0~30(Only limited to the combined use of an external

sensor with a BIS module)

EMG: 30~55dB(bar chart)with intensity between 30dB and

80dB(tendency chart)

BIS: 0~100

SQI: 0%~100%

SR: 0%~100%

SEF: 0.5Hz~30Hz

TP:40~100Db

EEG Measurement:

Input impedance>5MΩ

Noise(RTI)<2μV(0.25~50Hz)

Input signal range: ±1Mv

EEG bandwidth between: 0.25Hz~110Hz

 

NMT(Optional)

Microprocessor-controlled

Stimulation Mode: TOF, TOFS, PTC, 1Hz Twitch, 0.1Hz

Twitch ,DBS DBS3.3 and 3.2(Double Burst) , Tetanic

Stimulation (Burst), 5s – 50Hz or 100Hz

Output(accuracy±5% of full scale value)

Surface electrodes:

 Constant current,0-60mA(0-12/18μC) up to 5KOhm.

 Monophasic, 200μs or 300μs pulse width

Needle electrodes:

 Constant current,0-6mA(0-0.24μC) up to 5KOhm.

 Monophasic, 40μs pulse width

Acceleration transducer: Accuracy±5% of full scale value

Temperature sensor: Range 20.0-41.5℃(accuracy±5℃)

 

Operation Environment

Power: AC 100-250V, 50/60Hz

Temperature: 5-40℃

Humidity: <80%

Patient Range: Adult, Pediatric, Neonate

 

 

 


No reviews found

Not satisfied with the unit price? Get a free quote on bulk quantities within 8 hours.