Get a quotation upon your custom quantity
Anesthesia Workstation AEON-8800A(two vaporizers) Specification BASE UNIT Dimensions (H x W x D) Trolley version (with breathing circuit) 1420X770X760 mm Weight and load Trolley (without vaporizer and backup cylinder) 135 kg Top shelf load 25 kg...
+

Minimum quantity for "Anesthesia Workstation AEON-8800A(two vaporizers)" is 1.

Port: Shanghai,China
Payment
Share to

Anesthesia Workstation AEON-8800A(two vaporizers)

Specification

BASE UNIT

Dimensions (H x W x D)

Trolley version (with breathing circuit)

1420X770X760 mm

Weight and load

Trolley (without vaporizer and backup cylinder)

135 kg

Top shelf load

25 kg

Caster locking

Braking Types

Central brake system

Power and battery backup

Power input

AC100~240V,50/60Hz

Power outlets

4 sockets on back, 1.5A individual

Batteries and Operation time with fully charged

DC 24V. 4.0AH. Minimum 120 minutes

Environmental requirements

Operation temperature

10~40°C(50~104°F)

Operation humidity

<95% (non-condensing)

Storage temperature

-20~6応0~131午)

Storage humidity

<95% (non-condensing)

ANESTHESIAGASSUPPLYMODULE

 

Gas supply

O2, NzO, AIR; 280~600kPa

Cylinder yokes

Optional: Ch^NaO, AIR

Fresh gas flow indicator

Electronically controlled mixer

Range of fresh gas flow indicators

0T8L/min or set each gas independently: O2, N2O:0~10L/min; AIR: 0~12L/min

O2 flush

25-75 L/min

Auxiliary common gas outlet (ACGO)

Optional

Anesthetic Gas Scavenging System (AGSS)

Optional

Vaporizer

Agent

Sevoflurane, Halothane, Enflurane, Isoflurane

Installation mode

Selectatec' with interlock, optional standby vaporizer parking holder

Filling type

Pour-Fill  Key-Fill, Quik-Fil

Breathing system

Volume of CO2 absorber

1.5 L for single canister

APL Range

Spontaneous breathing FSP) -70 cm H2O

Material

Autoclavable (except O2 cell and airway pressure gauge)

Heating system

32-40 °C

CO2 bypass

Optional

VENTILATOR OPERATING SPECIFICATIONS

 

Ventilator

Pneumatically driven. Electronically controlled

Ventilation modes-standard

Manual/Spontaneous

Volume control (IPPV)

Pressure control (PCV)

Ventilation modes - options

Pressure Controlled Ventilation Volume Guaranteed (PCV-VG)

Synchronized Intermittent Mandatory Ventilation in Volume (SIMV-VC)

Synchronized Intermittent Mandatory Ventilation in Pressure (SIMV-PC)

Synchronized Intermittent Mandatory Ventilation in PCV-VG (SIMV-VG)

Pressure Support (PS)/ Continuos Positive Airway Pressure (CPAP)

Bilevel Positive Airway Pressure Ventilation (BIVENT)

Airway Pressure Release Ventilation (APRV)

Control input ranges

Breathing frequency (Freq)

2-100 bpm

Positive end expiratory pressure (PEEP)

OFF, 3-50cmH2O

Inspiration/expiration ratio (l:E)

4:1~1:8

Tidal volume (Vt)

10-1500 ml

Inspiration pause

OFF.5%-60%

Inspiratory time

0.2-5.0s

Inspiratory pressure (Ptabget)

5-70 cm H2O

Pressure support level (AP)

3~60cmH2。

Pressure limit (Pmax)

10-100 cmH2O

Trigger

0.5-15 L/min /-20~-lcmH20

Inspiratory Slope Time (T slope)

0~2s

Compensation

Compliance and Leak compensation, fresh gas compensation, altitude compensation

Ventilator monitoring & alarm

Monitoring

Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal

volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, l:E ratio.

resistance, compliance. Option: driving pressure, stress index, CO concentration,

paramagnetic oxygen analyzer, anesthetic gas concentration with MAC

Trend storage

Maximum 720 hours of trend data table, 72 hours of trend chart

Medical gas calculations

Consumption of CO2, N2O and Agent. Calculations of Co2 production, require relevant gas monitoring

Control screen

15" TFT color touch screen

Graph Display

Waveforms of P-t, F t, V-t, CO2-t (option), P-V Loop, V-F Loop, P-F Loop

Alarm

MV high/low limit F6 high/low limit, Paw high/low limit Pow er failure

High Freq, Negative pressure. Continuous airway pressure. Apnea alarm, etc.

Alarm (Silence <120 seconds)

Alarm logging

500 items