Anesthesia Workstation AEON-8600A
Anesthesia Workstation AEON-8600A
Specification
Technical Specifications | |
BASE UNIT | |
Dimensions(HxWxD) | |
Trolley version (with breathing circuit) | 1420×760×760 mm |
Weight and load | |
Trolley (without vaporizer and backup cylinder) | 135kg |
Top shelf load | 25 kg |
Caster locking | |
Braking Types | Ind iv idual locking front casters |
Power and battery backup | |
Power input | AC100~240V,50/60 Hz |
Power outlets | 4 sockets on back,1.5A individual |
Batteries and Operation time with fully charged | DC 24V,4.0AH, Minimum 120 minutes |
Environmental requirements | |
Operation temperature | 10~40℃ (50~104 °F) |
Operation humidity | ≤95%(non-condensing) |
Storage temperature | -20~60℃(-4~131°F) |
Storage humidity | ≤95%(non-condensing) |
ANESTHESIA GAS SUPPLY MODULE | |
Gas supply | O2,N2O,AIR;280~600kPa |
Cylinder yokes | Optional: O2, N₂O, AIR |
Fresh gas flow indicator | Electronic display flowmeter |
Range of fresh gas flow indicators | O2,N2O:0-10L/min;AIR:0-12L/min |
O2flush | 25~75L/min |
Auxiliary common gas outlet (ACGO) | Optional |
Anesthetic Gas Scavenging System (AGSS) | Optional |
Vaporizer | |
Agent | Sevoflurane, Halothane, Enflurane, Isoflurane |
Installation mode | Selectatec with interlock, optional standby vaporizer parking holder |
Filling type | Pour-Fill, Key-Fill, Quik-Fil' |
Breathing system | |
Volume of CO2 absorber | 1.5 Lfor single canister |
APL Range | Spontaneous breathing (SP)-70 cmH₂O |
Material | Autoclavable (except O2 cell and airway pressure gauge) |
Heating system | 32-40 ℃ |
CO₂ bypass | Optional |
VENTILATOR OPERATING SPECIFICATIONS | |
Ventilator | Pneumatically driven, Electronically controlled |
Ventilation modes- standard | Manual/Spontaneous |
Volume control (IPPV) | |
Pressure control(PCV) | |
Ventilation modes - options | Pressure Controlled Ventilation Volume Guaranteed (PCV-VG) |
Synchronized Intermittent Mandatory Ventilation in Volume (SIMV-VC) | |
Synchronized Intermittent Mandatory Ventilation in Pressure (SIMV-PC) | |
Synchronized Intermittent Mandatory Ventilation in PCV-VG (SIMV-VG) | |
Pressure Support(PS)/ Continuos Positive Airway Pressure (CPAP) | |
Bilevel Positive Airway Pressure Ventilation (BIVENT) | |
Airway Pressure Release Ventilation (APRV) | |
Control input ranges | |
Breathing frequency(Freq) | 2~100 bpm |
Positive end expiratory pressure (PEEP) | OFF,3~50 cmH₂O |
Inspiration/expiration ratio(I:E) | 4:1~1:8 |
Tidal volume (Vt) | 20~1500 ml |
Inspiration pause | OFF,5%~60>#/td### |
Inspiratory time | 0.2~5.0 s |
Inspiratory pressure (PTARGET) | 5~70 cmH2O |
Pressure support level(△P) | 3~60 cmH2O |
Pressure limit(Pmax) | 10~100 cmH₂O |
Trigger | 0.5~15L/min/-20~-1cmH₂O |
Inspiratory Slope Time(TsLopt) | 0~2s |
Compensation | Compliance and Leak compensation, fresh gas compensation, altitude compensat i on |
Ventilator monitoring & alarm | |
Monitoring | Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal |
volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, I:E ratio, | |
resistance,compliance. Option: driving preasure, stress index, CO2 concentration, | |
paramagnetic oxygen analyzer, anesthetic gas concentration with MAC | |
Trend storage | Maximum 720 hours of trend data table, 72 hours of trend chart |
Medical gas calculations | Consumption of Oz, N₂O and Agent. Calculations of CO2 production. require relevant gas monitoring |
Control screen | 12.1" TFT color touch screen |
Graph Display | Waveforms of P-t, F-t,V-t,CO2-t(option),P-V Loop,V-F Loop,P-FLoop |
Alarm | MV high/low limit, FiO2 high/low limit, Paw high/low limit, Power fai lure |
High Freq, Negative pressure, Continuous airway pressure, Apnea alarm, etc. | |
Alarm (Silence ≤120 seconds) | |
Alarm logging | 500 items |
Remark:Above configurations includestandard and option.Pleasecheck price with you Aeonmed salesrepresentative. |
No reviews found