40KW Digital Portable X Ray Device AG-LY-1800 DRM
40KW Digital Portable X-Ray Device AG-LY-1800 DRM
AG-LY-1800 DRM portable x-ray device is an economic and practical mobile digital X-ray device, can be widely used in radiology, orthopedic, medical examination department, emergency room, intensive care unit, operating room, and neonatal pediatrics, it fully meets the demand of hospital digital radiography.
♦ 40kw superpower high frequency and high voltage generator and high heat capacity ball tube provide powerful guarantee for high-quality X-ray output
♦ Wireless flat panel detector, get rid of cable bondage
♦ Wide nose angle, flexible positioning, hovering at any position within the angle range
♦ The battery has a large energy storage capacity and can be exposed 1500 times in full charge state
Specification
Part | Model | Main technical parameters and performance description |
High voltage generator ( imported components) | BWG-50 | Extemal charging general power suppy 220VAC. Lithium battery enery, full power can meet 200 times of exposure, remote exposure cotroller > 50m: Tube Voltage: 40kV-150kV ,Step Length: 1kV; Tube current:10mA-500mA,load time range: 0.01s-6.3s. Current time product range :0.1 mAs- 250 mAs, Output nominal electric power :40 kW (400 ma,100 kv,0.1s); Inverter input supply voltage :450 VDC/48VDC±10%; High voltage tansformer structure: non-working frquency |
X-ray tube | E7843X | Nominal tube voltage :150kV; Focus:0.6/1.2 mm; Target angle:12° ; Anode heat capacity:111kJ (150khu); Tube sleeve heat capacity:900KJ (1250khU) Anode Input power: large focus 50 kW, small focus 22kW; solid filter:1.3mm AI/75kV; Rotating anode, Rotational speed:3200 rpm |
Beam limiter | BRC-20 | mm AI/75kV;1.0 manual control; LED visual field indicator light: 360° Adjustable rotation angle. |
Amorphous silicon plate Detector | CareView 1800cw | Cesium iodide amorphous silicon plate. Pixel matrix:> 2816x2816; Imaging area: 17x17" Pixel Size: < 154umm, Spatial resolution: 3.5lp/mm,AD conversion 16bits; MTF:> 60%@1lp/mm> 20%@3lp/m DQE: (@ rqa5, 30µGy)>60%@0lp/mm > 15%@3lp/mm Dynamic range: > 80dB; Imaging time: original image output time <3 seconds, after loading software processing should be about 8 seconds |
Mobile frame | --- | The main wheel in front design: stable center of gravity; small turning radius; Light motion control;easy to push by manpower; Electromagnetic locking and fixation of the cross arm during trolley motion; Cross arm: front and back Movement range:≥250mm, up and down Movement range:≥1200mm; Ball tube can rotate vertically:+90°,-10°and horizontally ±180°; Heads with locking mechanisms can be locked at any angle. The column can be kneaded at ±180°, and the electromagnetic brake with power loss can be locked and fixed; |
DR image processing Software | PICKE-DA | DR diagnostic software:
DICOM3.0 criterial, pre-selection tips for cast position; Preset of image brightness/contrast, window width/window position; Preset of organization equalization technology; Preset of image enhancement and sharpening technology; Image segmentation, transmission, printing, etc. |
lmage Acquisition Station | BWS-20 | The minimum performance requirement for display:
Screen range:17"; Resolution: ≥1280x 1024 Minimum computer performance requirements: CPU≥i3, hard disk≥500G, memory≥4G; |
Documents | --- | Registration Document, Specification, and Product Certificate |