Anesthesia Workstation AEON-8800A(two vaporizers)
Anesthesia Workstation AEON-8800A(two vaporizers)
Specification
BASE UNIT | |
Dimensions (H x W x D) | |
Trolley version (with breathing circuit) | 1420X770X760 mm |
Weight and load | |
Trolley (without vaporizer and backup cylinder) | 135 kg |
Top shelf load | 25 kg |
Caster locking | |
Braking Types | Central brake system |
Power and battery backup | |
Power input | AC100~240V,50/60Hz |
Power outlets | 4 sockets on back, 1.5A individual |
Batteries and Operation time with fully charged | DC 24V. 4.0AH. Minimum 120 minutes |
Environmental requirements | |
Operation temperature | 10~40°C(50~104°F) |
Operation humidity | <95% (non-condensing) |
Storage temperature | -20~6応0~131午) |
Storage humidity | <95% (non-condensing) |
ANESTHESIAGASSUPPLYMODULE |
|
Gas supply | O2, NzO, AIR; 280~600kPa |
Cylinder yokes | Optional: Ch^NaO, AIR |
Fresh gas flow indicator | Electronically controlled mixer |
Range of fresh gas flow indicators | 0T8L/min or set each gas independently: O2, N2O:0~10L/min; AIR: 0~12L/min |
O2 flush | 25-75 L/min |
Auxiliary common gas outlet (ACGO) | Optional |
Anesthetic Gas Scavenging System (AGSS) | Optional |
Vaporizer | |
Agent | Sevoflurane, Halothane, Enflurane, Isoflurane |
Installation mode | Selectatec' with interlock, optional standby vaporizer parking holder |
Filling type | Pour-Fill Key-Fill, Quik-Fil |
Breathing system | |
Volume of CO2 absorber | 1.5 L for single canister |
APL Range | Spontaneous breathing FSP) -70 cm H2O |
Material | Autoclavable (except O2 cell and airway pressure gauge) |
Heating system | 32-40 °C |
CO2 bypass | Optional |
VENTILATOR OPERATING SPECIFICATIONS |
|
Ventilator | Pneumatically driven. Electronically controlled |
Ventilation modes-standard | Manual/Spontaneous |
Volume control (IPPV) | |
Pressure control (PCV) | |
Ventilation modes - options | Pressure Controlled Ventilation Volume Guaranteed (PCV-VG) |
Synchronized Intermittent Mandatory Ventilation in Volume (SIMV-VC) | |
Synchronized Intermittent Mandatory Ventilation in Pressure (SIMV-PC) | |
Synchronized Intermittent Mandatory Ventilation in PCV-VG (SIMV-VG) | |
Pressure Support (PS)/ Continuos Positive Airway Pressure (CPAP) | |
Bilevel Positive Airway Pressure Ventilation (BIVENT) | |
Airway Pressure Release Ventilation (APRV) | |
Control input ranges | |
Breathing frequency (Freq) | 2-100 bpm |
Positive end expiratory pressure (PEEP) | OFF, 3-50cmH2O |
Inspiration/expiration ratio (l:E) | 4:1~1:8 |
Tidal volume (Vt) | 10-1500 ml |
Inspiration pause | OFF.5%-60% |
Inspiratory time | 0.2-5.0s |
Inspiratory pressure (Ptabget) | 5-70 cm H2O |
Pressure support level (AP) | 3~60cmH2。 |
Pressure limit (Pmax) | 10-100 cmH2O |
Trigger | 0.5-15 L/min /-20~-lcmH20 |
Inspiratory Slope Time (T slope) | 0~2s |
Compensation | Compliance and Leak compensation, fresh gas compensation, altitude compensation |
Ventilator monitoring & alarm | |
Monitoring | Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal |
volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, l:E ratio. | |
resistance, compliance. Option: driving pressure, stress index, CO concentration, | |
paramagnetic oxygen analyzer, anesthetic gas concentration with MAC | |
Trend storage | Maximum 720 hours of trend data table, 72 hours of trend chart |
Medical gas calculations | Consumption of CO2, N2O and Agent. Calculations of Co2 production, require relevant gas monitoring |
Control screen | 15" TFT color touch screen |
Graph Display | Waveforms of P-t, F t, V-t, CO2-t (option), P-V Loop, V-F Loop, P-F Loop |
Alarm | MV high/low limit F6 high/low limit, Paw high/low limit Pow er failure |
High Freq, Negative pressure. Continuous airway pressure. Apnea alarm, etc. | |
Alarm (Silence <120 seconds) | |
Alarm logging | 500 items |