AG-D0014 High-frequency Electric Surgical Knives
AG-D0014 High-frequency Electric Surgical Knives
Specification
1. Model AG-D0014
2. Host size 41x32x14 CM
3. Packing size 52 x43x25 CM
4. Weight 8 KG
Parameter
1.Ambient temperature range: 5 ℃ -40 ℃
2. Atmospheric pressure range: 86--106Kpa
3. The voltage and frequency: 110V / 60Hz, 220V / 50Hz
4. Operating frequency: 540 KHz
5. All microcomputer control Touch control panel design, the output power of the digital display,
accompanied by different sound and light indication output.
6. Floating-pull output Electric knife high-frequency current output by the negative plates returned to
the host, avoid the possibility of the patient's body other ground parts of burns
fundamentally, such as infusion pumps, ECG electrodes, operating table, which
may make the patient's body grounded place.
7. Monopolar and bipolar Have hand control and foot control mode
8. Monopolar and bipolar have hand control and foot control mode Precise power control and a wide range of power output can meet the need for surgery
9. Negative plate prepared patient contact quality inspection system (REM) The quality of contact between the negative plate and the patient's skin is detected in real time. Once the contact area is reduced, the REM resistance increases to an unsafe level and the machine automatically alarms and stops output.
Model | AG-D0014 |
Host size | 41x32x14 CM |
Packing size | 52 x43x25 CM |
Weight | 8 KG |
Parameter | 1. Ambient temperature range: 5 ℃ -40 ℃ |
2. Atmospheric pressure range: 86--106Kpa | |
3. The voltage and frequency: 110V / 60Hz, 220V / 50Hz | |
4. Operating frequency: 540 KHz | |
◆ All microcomputer control | Touch control panel design, the output power of the digital display, |
accompanied by different sound and light indication output. | |
◆ Floating-pull output | Electric knife high-frequency current output by the negative plates returned to |
the host, avoid the possibility of the patient's body other ground parts of burns | |
fundamentally, such as infusion pumps, ECG electrodes, operating table, which | |
may make the patient's body grounded place. | |
◆ Monopolar and bipolar | Have hand control and foot control mode |
◆ Monopolar and bipolar have hand control and foot control mode | Precise power control and a wide range of power output can meet the need for |
surgery | |
◆ Negative plate prepared patient contact quality inspection system (REM) | The quality of contact between the negative plate and the patient's skin is detected in real time. Once the contact area is reduced, the REM resistance increases to an unsafe level and the machine automatically alarms and stops output. |