Medical Grade Fetal Doppler BF-610P

Escribe una opinión
BF-610P
En stock
Price: click login to view
Get a quotation upon your custom quantity
  • Safety Classification: BF/Class Ⅱ/Internal Power
  • Transducer Working Frequency: 2.0 MHz,3.0 MHz(option),5.0 MHz(option) ,(±10%)
  • Ultrasound Average Intensity: ≤10mW/cm2
  • Input Voltage: A.C. 110V~240V,50Hz±1Hz
  • Heart Rate Detecting Range: 50bpm —240bpm
  • Built-In 14.4V Ni-MH Rechargeable Battery
  • 3.2'' Color TFT 
+

La cantidad mínima para el "Medical Grade Fetal Doppler BF-610P" es 10.

Port: Shanghai,China
Pago
Share to

Medical Grade Fetal Doppler BF-610P

BF-610P fetal doppler is used to listen to the heartbeat of a developing baby. The doppler emits sound waves that are picked up by a special probe and then amplified so that they can be heard through headphones or speakers. Many expectant parents choose to use a fetal doppler during their pregnancy as it provides reassurance that their baby's heartbeat is healthy and strong. Listening to the heartbeat can also be a bonding experience for both parents and children.

Function

◆  Portable Fetal Doppler mainly applies to detect the fetal heartbeat rate from the 12th week;
◆  Built-in rechargeable battery can work continuously for more than 4 hours;
◆  3.2'' color TFT can clearly display FHR data or graphic, heart rate graphics, battery indicator, the volume of sound, and synchronous FHR signal;
◆  Store and hold FHR data and graphics for up to 12 hours (for option);
◆  BF-610P built-in thermal printer can synchronously  print the FHR curve clearly and delicately;
◆  Alarm function when FHR is out of the normal range or battery power is in shortage;
◆  Probes with high sensitivity can detect FHR and umbilical blood steam and are much easier to interchange;
◆  Various frequency probes for different use.(for option);
◆  Normative collocation: 2.0 MHz
◆  RS-232 port can connect the unit with a computer and store the data.
◆  Software is an option.

Specifications

Standard EN61266: 2002 
Safety Classification  BF/Class Ⅱ/Internal Power
Transducer working frequency  2.0 MHz、3.0 MHz(option) 、5.0 MHz(option) ;(±10%).
Ultrasound average intensity  ≤10mW/cm2
Overall Sensitivity  ≥90 dB
The overall Sensitivity of placed 200mm away from the surface of the probe, which is 200mm away from the surface probe; 
While detecting the overall Sensitivity, the adopted frequency is (300±50)Hz, and the reflecting target speed is 10cm/s~40cm/s.
The effective area of the transducer 6.0 ± 0.5 cm2(2MHz)
Spatial-peak /temp-peak acoustic pressure ≤ 0.1 MPa
Input Voltage A.C. 110V~240V  50Hz±1 Hz
Adapter output voltage DC 24V±2V
Input power ≤ 20VA
Heart rate detecting range  50bpm —240 bpm
Built-in battery  14.4V Ni-MH rechargeable battery
Audio maximum output power  ≥1.8 W
Suggested  coupling  impedance  1.5—1.6(105g/cm2.s)
Static continuously working time
(when the battery is full of power and it is at the self-detect time)
> 8
Doppler Frequency 100—5000 Hz
Working environment 
Temperature +5 ℃ ~ +40 ℃ 
Humidity  ≤ 80%  
Atmospheric pressure  86kPa ~ 106kPa
Transport and storage environment   
Temperature  -10 ℃ ~ +40 ℃ 
Humidity  ≤ 80% 
Atmospheric pressure  86kPa ~ 106kPa, well-ventilated room without corrosive gases.
PS Acoustic output parameters meet the national exempted conditions which released that the ultrasonic and main unit in all operating modes can meet the following requirements
a) The peak negative acoustic pressure (p_) <1Mpa
b) The output beam of sound intensity (lob)  <20mW/cm2
c) Spatial peak time average educed the sound intensity (lspta)  <100mW/cm2