AG-BZ003-B Patient Monitor For Hospital ICU and General Diagnosis
AG-BZ003-B Patient Monitor For Hospital ICU and General Diagnosis
Specification
1)12V DC power supply for ambulance use
2) An optional HDMI output eases observation from a long distance.
Dimension and Weight | Dimension:210mm*130mm*75mm Weight: 1kg(excluding accessories) |
Power Supply | Voltage: AC100~240V, 50/60HZ Adapter: Output 9VDC, 5A |
Display | 7" color TFT LED Resolution: 800*480 pixels |
Battery | Type: Rechargeable lithium battery 7.4V/2200mAh Charge Cycle: ≥500 times Working time: 2-3 hours (optional larger battery for 4-5 hours) |
Recorder (Option) | Method: USB External Thermal printer Paper width: 50 mm (1.97 in) Printing speed: 12.5/ 25/ 50 mm/s Trace: Max. 3 tracks Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording |
Alarm | Level: Low, medium and high
Indication: Auditory and visual Alarm volume adjustable Alarm pause time: 1min, 2min Parameter alarm type: Latch/ Unlatch |
Input Device | Touch screen (standard) Touch pen (standard) |
System Output & Extensible Interface | Ethernet Network: 1 standard RJ45 socket
USB Port: 1 Video Output: 1 HDMI port (option) |
Operating Environment | Temperature: 5 ~ 40 ℃
Humidity: 15% ~ 80% (non-condensing) Atmosphere pressure: 86 KPa ~ 110 KPa |
Transportation and Storage Environment | Temperature: -20~50 ℃
Humidity: 10%~90% (non-condensing) Atmosphere pressure: 86 KPa ~ 110 KPa |
Safety | IEC60601-1 Approved, CE marking according to MDD93/42/EEC With reference to RoHS Directive 2011/65/EU recasting |
Trend & Reviewing | Trend: 2160 hours
ARR events: 128 groups of ARR events and associated waveform NIBP measurement reviewing: 2000 groups Waveform review: 2 hours Alarm event: 2000 groups of parameter alarms events and associated parameter |
Heart Rate | Measure range:
Adult: 0bpm; 10 ~ 300 bpm Neo/Ped: 0bpm; 10 ~ 350 bpm Resolution: 1 bpm Accuracy: ± 1% or ± 1bpm, whichever is greater |
NIBP | Method: Oscillometric
Measure mode: Manual, Auto, STAT Measure Interval in AUTO Mode: 1~480 min STAT mode cycle time: Keep 5 minutes, at 5 seconds interval Static pressure accuracy: ±3mmHg Resolution: 1mmHg Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation: ≤8mmHg Overpressure Protection: Dual protection via software & hardware |
NIBP | Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 235 mmHg Pediatric: SYS: 40 ~ 235 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 225 mmHg Neonate:SYS: 30 ~ 135 mmHg DIA: 10 ~ 110 mmHg MEAN: 20 ~ 125 mmHg |
Model Configuration
Standard Config. | With 7’ LED, Touch Screen SpO2+NIBP+PR+ TEMP |
Optional Config. | Nellcor SpO2, Masimo SpO2, Suntech NIBP, Infrared thermometry |
Optional Accessories: | Printer, HDMI Output, Wall-mounting, Trolley, Bed Hanger Central Monitoring Station Neo/Ped Accessories |