Medical Grade Fetal Doppler BF-610P
Medical Grade Fetal Doppler BF-610P
BF-610P fetal doppler is used to listen to the heartbeat of a developing baby. The doppler emits sound waves that are picked up by a special probe and then amplified so that they can be heard through headphones or speakers. Many expectant parents choose to use a fetal doppler during their pregnancy as it provides reassurance that their baby's heartbeat is healthy and strong. Listening to the heartbeat can also be a bonding experience for both parents and children.
Function
◆ Portable Fetal Doppler mainly applies to detect the fetal heartbeat rate from the 12th week;
◆ Built-in rechargeable battery can work continuously for more than 4 hours;
◆ 3.2'' color TFT can clearly display FHR data or graphic, heart rate graphics, battery indicator, the volume of sound, and synchronous FHR signal;
◆ Store and hold FHR data and graphics for up to 12 hours (for option);
◆ BF-610P built-in thermal printer can synchronously print the FHR curve clearly and delicately;
◆ Alarm function when FHR is out of the normal range or battery power is in shortage;
◆ Probes with high sensitivity can detect FHR and umbilical blood steam and are much easier to interchange;
◆ Various frequency probes for different use.(for option);
◆ Normative collocation: 2.0 MHz
◆ RS-232 port can connect the unit with a computer and store the data.
◆ Software is an option.
Specifications
Standard | EN61266: 2002 |
Safety Classification | BF/Class Ⅱ/Internal Power |
Transducer working frequency | 2.0 MHz、3.0 MHz(option) 、5.0 MHz(option) ;(±10%). |
Ultrasound average intensity | ≤10mW/cm2 |
Overall Sensitivity | ≥90 dB The overall Sensitivity of placed 200mm away from the surface of the probe, which is 200mm away from the surface probe; While detecting the overall Sensitivity, the adopted frequency is (300±50)Hz, and the reflecting target speed is 10cm/s~40cm/s. |
The effective area of the transducer | 6.0 ± 0.5 cm2(2MHz) |
Spatial-peak /temp-peak acoustic pressure | ≤ 0.1 MPa |
Input Voltage | A.C. 110V~240V 50Hz±1 Hz |
Adapter output voltage | DC 24V±2V |
Input power | ≤ 20VA |
Heart rate detecting range | 50bpm —240 bpm |
Built-in battery | 14.4V Ni-MH rechargeable battery |
Audio maximum output power | ≥1.8 W |
Suggested coupling impedance | 1.5—1.6(105g/cm2.s) |
Static continuously working time (when the battery is full of power and it is at the self-detect time) | > 8 |
Doppler Frequency | 100—5000 Hz |
Working environment | |
Temperature | +5 ℃ ~ +40 ℃ |
Humidity | ≤ 80% |
Atmospheric pressure | 86kPa ~ 106kPa |
Transport and storage environment | |
Temperature | -10 ℃ ~ +40 ℃ |
Humidity | ≤ 80% |
Atmospheric pressure | 86kPa ~ 106kPa, well-ventilated room without corrosive gases. |
PS | Acoustic output parameters meet the national exempted conditions which released that the ultrasonic and main unit in all operating modes can meet the following requirements |
a) The peak negative acoustic pressure (p_) | <1Mpa |
b) The output beam of sound intensity (lob) | <20mW/cm2 |
c) Spatial peak time average educed the sound intensity (lspta) | <100mW/cm2 |