This portable cardiovascular ultrasound machine comes with an ultrasonic host operating system with Windows 7 operating system, widely applied to abdominal, OB/GYN, Cardiac, Urinary, Small Parts, Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc.
Besides, it has various probes for different diagnoses, including convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, cardiac probe, and 4D volume probe.
1 | Summary of main specifications and system of portable type all digital color Doppler ultrasound |
1.2 | Carotid artery intima measurement thickness(IMT ) |
1.3 | Automatic spectral envelope measurement |
1.4 | Full digital transmission and reception of beam synthesizer |
1.5 | Color Doppler imaging ( C ) Pulse-Doppler Imaging ( PW ) Coherent Contrast imaging ( CCI ) Continuous-wave Doppler imaging ( CW ) |
1.6 | B/C/D Real-time three synchronous imaging |
1.7 | Power Doppler imaging ( PDI ) Direct power Doppler imaging ( DPDI ) Anatomic M mode imaging Color Doppler M mode imaging |
1.8 | Elastography Tissue Doppler imaging ( TDI ) Strain rate imaging (SRI) Tissue harmonic imaging ( THI ) Fusion harmonic imaging ( FHI ) Speckle Reduce imaging ( SRI ) Deflection imaging Trapezoidal imaging |
1.9 | Adaptive velocity optimization |
1.91 | Freehand 3D Real-time 3D imaging ( 3D/4D ) DICOM3.0 |
Monitor | ≥15 inches, high definition ultrasonic display |
Battery | Built-in rechargeable battery |
Physical clipboard | Save the image on the left side of the screen, which can be directly saved or deleted. |
1.92 | The system has the function of an on-the-spot upgrade |
Presupposition | for different inspections of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
Probe interface | 2 |
Language | Chinese/English/German/Russian/Spanish/French/Arabic/Vietnamese/Portuguese/Indonesian |
Depth | ≥360mm |
1.93 | Extended imaging |
2 | Probes |
2.1 Convex probe | Fundamental Frequency : 2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz, Harmonic Frequency:4.0MHz/4.6MHz/5.0MHz |
2.2 Linear probe | Fundamental Frequency :4.0MHz /4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz /10.0MHz /12.0MHz/13.3MHz , Harmonic Frequency :8.0MHz/9.2MHz/10.0MHz |
2.3 Trans-vaginal probe | Fundamental Frequency :3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz , Harmonic Frequency :6.0MHz/7.0MHz/8.0MHz |
2.4 Micro-convex probe | Fundamental Frequency :3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz , Harmonic Frequency:6.0MHz/7.0MHz/8.0MHz |
2.5Cardiac probe | Fundamental Frequency : 1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz , Harmonic Frequency:3.4MHz/3.8MHz/4.2MHz |
2.6 4D Volume probe | Fundamental Frequency :2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz , Harmonic Frequency:4.0MHz/5.0MHz/6.0MHz, |
3 | 2D imaging mode |
Gain | 0-100, Step 2 adjustable |
TGC | 8 segments adjustable |
Maximum focus point | ≥7, which can be moved throughout the whole process. |
Speckle reduction | 0-5, 5 level |
Space Synthesis | 0-2, 2 levels ( Liner probe: 3 levels, cardiac probe:0 ) |
Dynamic | 30-180, 35 levels, step 5 adjustable |
Line density | low、middle、high, 3 level |
Frame correlation | 0-4,4 level |
Noise reduction | 0-5,5 level |
Edge Enhancement | 0-5,5 level |
3.1 | Sound power: 2-10, 9 level Greyscale : 0-67, 67 level False-color : 0-67 , 67 level Image style: Soft-Comparison, 2 level |
3.2 | The screen has a real-time display of voice power, probe frequency, dynamic range, pseudocolor, grayscale, and other 11 parameters that can be adjusted |
4 | Color Doppler imaging mode |
4.1 | Blood gain : 0-100, Step 2 |
4.2 | Parameter display: Velocity、Variance |
4.3 | B-Restrain ( B/W restrain ) : 0-7, 7 level |
4.4 | Speed Through : 0-8, 8 level |
4.5 | Sampling number: 6-24, 7 level |
4.6 | Blood flow preferred : 0-8, 8 level |
4.7 | Filtering: 1-6, 6 level |
4.8 | Sound power: 2-6, 4 level |
4.9 | Noise reduction : 0-4, 4 level |
4.10 | Smooth treatment : 0-4, 4 level |
4.11 | Frame correlation : 0-6 , 6 level |
4.12 | Chromatography ( Blood flow graph ) : 0-37 , 37 level |
4.13 | Line density: Low-Middle-High, 3 level |
4.14 | Frequency: 4 level adjustable |
4.15 | Velocity: Minimum 0.4K, Maximum 40.5K Convex probe : 0.4K-4.3K-38.5K Linear probe : 0.4K-14.7K-39.0K Trans-vaginal probe : 0.4K-7.8K-39.7K Volume probe: 0.4K-4.2K-34.8K Micro-convex probe : 0.4K-10.3K-40.5K cardiac probe: 0.4K-7.8K-39.7K |
PS : | The frequency of the probe changes and the frequency value changes Frame rate changes with speed |
5 | Pulse wave Doppler ( PW ) |
5.1 | Gain : 0-100, Step 2 |
5.2 | Spectrum envelope function: real-time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR, and so on. Can wake up or close |
5.3 | Sample volume : 0.5mm~30mm |
5.4 | Blood angel: -75—75 degree, Step 5 |
5.5 | False-color : 0-67,67 level |
5.6 | Dynamic range: 20-40,4 level |
5.7 | Filter : 0-9,9 level |
5.8 | Smooth treatment: 1-4,4 level |
5.9 | Sound power: 2-5,4 level |
5.10 | Volume : 0-100, 10 level , Step 10 |
5.11 | Audio filtering : 0-4, 4 level |
5.12 | Baseline : -1.0~1.0, |
5.13 | Grey map : 0-67, 67 level |
5.14 | Scan velocity: 100-500, 6 level |
5.15 | PRF:Minimum 0.5K , Maximum 87.5K Convex probe : 0.5K-4.3K-63.3K Linear probe : 0.5K-14.5K-78.4K Trans-vaginal probe : 0.5K-8.1K-78.4K Volume probe : 0.5K-4.2K-53.8K Micro-convex probe : 0.5K-10.3K-81.1K Cardiac probe : 0.5K-4.3K-87.5K |
5.16 | Frequency: 4 level |
PS : | The frequency of the probe changes and the PRF value changes |
PS : | The frequency of the probe changes and the frequency value changes |
6 | Continuous Wave Doppler ( CW ) |
6.1 | Support probe: Cardiac probe |
6.2 | Adjustment of B mode parameters is switchable |
6.3 | Gain : 0-100, Step 2 |
6.4 | The sampling line position is adjustable |
6.5 | PRF:0.9K~36.1K |
6.6 | Baseline : -1.0~1.0 |
6.7 | Blood angel: -75~75 degree |
6.8 | Grey map : 0-67 |
6.9 | Scan velocity: 100-300 |
6.10 | False-color : 0-67 |
6.11 | Dynamic range: 20-40 |
6.12 | Filtering : 0-9 , 9 level |
6.13 | Smooth treatment: 1-4 |
6.14 | Frequency : 2.0MHz/2.3MHz/2.5MHz/3.0MHz , 4 level adjustable |
6.15 | Sound power: 2-5 |
6.16 | Volume : 0-100 |
6.17 | Audio Filtering : 0-4 |
☆7 | Anatomical M imaging |
7.1 | Support probe: Convex probe, Linear probe, Cardiac probe |
7.2 | Adjustment of B mode parameters is switchable |
7.3 | Gain : 0-100, Step 2 |
7.4 | M Sampling line angle is adjustable |
7.5 | M Sampling line length is adjustable |
7.6 | Sampling line : 3, Can be displayed or hidden separately |
☆8 | Blood flow M model ( MC ) |
8.1 | Adjustment of B mode parameters is switchable |
8.2 | Gain : 0-100, Step2 |
8.3 | MC Sampling line angle is adjustable |
8.4 | MC Sampling line length is adjustable |
8.5 | Frequency: 4 level |
8.6 | Sampling number: 6-24 |
8.7 | Speed through : 0-8, 8 level |
8.8 | Scan velocity: 150-500 |
8.9 | Frame correlation : 0-6, 6 level |
8.10 | Filtering: 1-6, 6 level |
8.11 | Blood flow preferred : 0-8, 8 level |
8.12 | Smooth treatment : 0-4,4 level |
8.13 | Map : 0-37, 37 level |
☆9 | Elastography |
9.1 | Adjustment of B mode parameters is switchable |
9.2 | Gain : 0-100, Step 2 |
9.3 | B/E, Double real-time display on the same screen |
9.4 | Probe displacement curve display: Up/Down |
9.5 | Pressure indicator bar display |
9.6 | Frequency: 8-9 level, Adjustable; According to the probe display |
9.7 | Noise reduction : 0-2, 2 level |
9.8 | Frame correlation : 0-3, 3 level |
9.9 | Comparison : 0-13, 13 level |
9.10 | False-color : 0-3 , 3 level |
9.11 | Don’t support cardiac probe |
☆10 | Tissue Doppler imaging ( TDI ) |
10.1 | Support probe: Cardiac probe |
10.2 | Adjustment of B mode parameters is switchable |
10.3 | Gain : 0-100, step 2 |
10.4 | ROI area adjustable |
10.5 | Sampling number: 6-24 |
10.6 | Velocity : 0.4K-8.0K |
10.7 | Frame correlation : 0-6, 6 level |
10.8 | Tissue preferred : 0-7, 7 level |
10.9 | Frequency : 2.0MHz/2.3MHz/2.5MHz/3.0MHz |
10.10 | Support color reversal |
☆11 | Strain rate imaging |
11.1 | Support probe: Cardiac probe |
11.2 | Adjustment of B mode parameters is switchable |
11.3 | ROI area adjustable |
11.4 | Gain : 0-100, Step 2 |
11.5 | Sampling number: 6-24, 6 level |
11.6 | Axial average: 1-4, 4 level |
11.7 | Velocity: 0.4K-8K |
11.8 | Frame correlation : 0-6 , 6 level |
11.9 | Tissue optimization : 0-7 , 7 level |
☆12 | Panoramic imaging |
12.1 | Support probe: Linear probe |
12.2 | Speckle Reduction : 0-5, 5 level |
☆13 | Deflection imaging |
13.1 | Support probe: Linear probe |
13.2 | Adjustment of B mode parameters is switchable |
13.3 | Deflection angel: 8 level |
13.4 | Speckle reduction : 0-5, 5 level |
13.5 | Dynamic rate: 30-180, Step 5 |
13.6 | Line density : low-middle-high , 3 level |
13.7 | Frame Correlation : 0-4 , 4 level |
13.8 | False-color : 0-67, 67 level |
13.9 | Image style : Soft-Comparison, 2 level |
13.10 | Noise reduction : 0-5, 5 level |
13.11 | Edge Enhancement : 0-5 , 5 level |
13.12 | Sound power: 2-10, 8 level |
13.13 | Grey map : 0-67, 67 level |
☆14 | Trapezoidal imaging |
14.1 | Probe support: linear probe |
14.2 | Adjustment of B mode parameters is switchable |
14.3 | Deflection angel: 8 level |
14.4 | Speckle reduction : 0-5, 5 level |
14.5 | Dynamic rate: 30-180, Step 5 |
14.6 | Line density : low-middle-high , 3 level |
14.7 | Frame Correlation : 0-4 , 4 level |
14.8 | False-color : 0-67, 67 level |
14.9 | Image style: Soft-Comparison, 2 level |
14.10 | Noise reduction : 0-5, 5 level |
14.11 | Edge Enhancement : 0-5 , 5 level |
14.12 | Sound power : 2-10 , 8 level |
14.13 | Grey map : 0-67 , 67 level |
14.14 | Space Synthesis : 0-2, 2 level |
☆15 | Freehand 3D imaging |
15.1 | Support probe : convex probe, linear probe |
15.2 | Display model: 4 pictures |
15.3 | Image Rotation X/Y/Z Axis |
15.4 | Multi-slice Visibility |
16 | Real-time 4D imaging |
16.1 | Support probe: 4D volume probe |
16.2 | Adjustment of B mode parameters is switchable |
16.3 | Gain : 0-100 , Step 2 |
16.4 | Display model : one image、two images、four images |
16.5 | Image Rotation : X/Y/Z Axis |
16.6 | Multi-slice Visibility |
16.7 | Light&Shade inversion |
16.8 | Smooth : 0-4, 4 level |
16.9 | Threshold level : 0-129, Step 3 |
16.10 | Transparency : 1-509 , Step 10 |
16.11 | Render type : 4 kinds , Surface、maximum、minimum、perspective |
17 | Extended Imaging |
17.1 | Gain : 0-100 , Step 2 |
17.2 | TGC : 8 segment adjustable |
17.3 | Maximum focus point : ≥7, which can be moved throughout the whole process. |
17.4 | Speckle reduction : 0-5 , 5 level |
17.5 | Space Compound : 0-2 , 2 level ( Linear probe: 3 level , don’t support cardiac probe ) |
17.6 | Dynamic range : 30-180 , 35 level , Step 5 |
17.7 | Line density : Low、Middle、High , 3 level |
17.8 | Frame correlation : 0-4,4 level |
17.9 | Noise reduction : 0-5 , 5 level |
17.10 | Edge enhancement : 0-5 , 5 level |
17.11 | Sound power : 2-10, 9 level |
17.12 | Grey map : 0-67, 67 level |
17.13 | False color : 0-67 , 67 level |
17.14 | Image style : Soft-Comparison, 2 level |
17.15 | Extended level: Maximum 72 level Convex probe : 9 level Trans-vaginal probe : 72 level Micro-convex probe : 29 level Cardiac probe : 40 level 4D Volume probe : 17 level |
PS : | The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted |
PS : | When the probe scan range reaches the maximum, the space synthesized is 0. |
18 | Measurement and analysis function: |
18.1 | General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle, etc. |
18.2 | Cardiac : Automatic spectrum envelope、LV、Main Pulmonary artery diameter、RVEDd、RVEDs、LVM、LAV、HR、MVF、AO、AR、LVOT、TVF、Pulmonic valve、Pulmonary vein、RV、Doppler fetal heart sound、LVET、LVM、LVMI、AV, etc. |
18.3 | Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) |
18.4 | OB : Fetal routine、AFI、TW、GS、CRl、OFD、HL、ulna、NT、Fibula、Nbonel、Radial、Tibia |
18.5 | GYN : uterus、cervix、corpus uteri/cervix uterus、left ovarian vein、right ovarian vein、dominant follicle、intima thickness , etc. |
18.6 | Urology: prostate、residual urine、left kidney、right kidney、left suprarenal vein、right suprarenal、left testis、right testis、left seminal vesicle、right seminal vesicle , etc. |
18.7 | Abdomen : liver、CHD、partal vein diameter、cholecyst、CBD、pancreas、spleen、Internal diameter of abdominal aorta、kidney , etc. |
18.8 | Small parts : Thyroid, etc. |
18.9 | Software package : Measurement package、Software package、Medical records management software package , etc. |
19 | Graphic and text management system |
19.1 | Host build in 2 hard disk ( SSD 120+1T ) , Start fast and stable |
19.2 | Movie playback : ≥1200 frames |
19.3 | Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on. |
19.4 | Type of report is 16 |
19.5 | One key fast report graphic and text management |
20 | Interface |
20.1 | USB interface: 2 HDMI interface: 1 RJ-45 interface: 1 Grounding wire interface: 1 |
21 | Configuration |
21.1 | Portable type full digital color Doppler ultrasound diagnostic system |
21.2 | Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional) |
21.3 | ≥13 quick-adjusting knobs |
22 | Technology, after-sales service, and other requirements |
22.1 | After acceptance, the warranty is free for two years ( Provide manufacturer warranty certificate ) |
22.2 | The manufacturer has ISO13485 certification and EU CE certification. |
Packing Details:
Metal case size: 71*43*55cm
N.W. 20kgs
G.W. 25kgs
No reviews found