Patient Monitor AG-MDWBZ026

Write a review
AG-MDWBZ026
In stock
Price: click login to view
Get a quotation upon your custom quantity
Patient Monitor AG-MDWBZ026 Specification Dimension and Weight 17.3” model - 440mm*145mm*310mm - Weight: 2.95kg / 4.0kg (excluding accessories) Power Supply - Voltage: AC100~240V, 50/60HZ, Power≤60W Display - 12.1" color TFT LED resolution: 800*600 pixels - 17.3" color TFT LED resolution:...
+

Minimum quantity for "Patient Monitor AG-MDWBZ026" is 1.

Port: Shanghai,China
Payment
Share to

Patient Monitor AG-MDWBZ026
Specification

Dimension and Weight
17.3” model - 440mm*145mm*310mm
- Weight: 2.95kg / 4.0kg (excluding accessories)
Power Supply
- Voltage: AC100~240V, 50/60HZ, Power≤60W
Display
- 12.1" color TFT LED resolution: 800*600 pixels
- 17.3" color TFT LED resolution: 1920*1080 pixels
Battery
- Type: Rechargeable lithium battery 12V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2 hours (optional larger capacity battery for 4-
5 hours)
Recorder (Option)
- Method: Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 12.5/ 25/ 50 mm/s
- Trace: Max. 3 tracks
- Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording
Alarm
- Level: Low, medium and high, message
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 1min, 2min, 5min
- Parameter alarm type: Latch/ Unlatch
Input Device
- Standard: Knob /Keypress
- Option: USB Mouse / USB Keyboard / Touch screen
System Output & Extensible Interface
- Ethernet Network: standard RJ45 socket * 1pc
- USB Port: 1pc
- Video Output: HDMI port (option) * 1pc
Operating Environment
- Temperature: 5 ~ 40 ℃
- Humidity: 15% ~ 90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Transportation and Storage
- Temperature: -20~50 ℃
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Safety
- IEC60601-1 Approved, CE marking according to
MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
- Trend: 2160 hours
- ARR events: 128 groups of ARR events and associated
waveform
- NIBP measurement reviewing: 2000 groups
- Waveform review: 2 hours ((expandable to 168 hours)
- Alarm event: 2000 groups of parameter alarms events and
associated parameter
SpO2 (Unicare, digital)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: ±2% (70% ~ 100%) ±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
- Support Pitch tone and multi-level volume
- Scan speed: 6.25, 12.5, 25, 50 mm/s
- PI range (Option):0.075%-20%
- Pleth Variability Index Measurement Range: 0 - 100%
Pulse Rate
- Measuring and Alarm Range: 20~250bpm
- Accuracy: ±1% or ±1 bpm, whichever is greater
- Resolution: 1bpm
Nellcor-SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: 70% ~ 100%, ±2 % (adult) 70% ~ 100%, ±3 % (Neonate) 70% ~ 100%, ±2 % (Low Perfusion) 0% ~ 69%, unspecified
Pulse Rate
- Measurement range: 20 ~ 300 bpm
- Resolution: 1bpm
- Accuracy:
±3 bpm (20 ~ 250 bpm)
unspecified (251~300 bpm)
Masimo SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy:
70% ~ 100%, ±2 % (adult/ pediatric, non-motion
conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
Pulse Rate
- Measurement range: 25 ~ 240 bpm
- Resolution: 1bpm
- Accuracy: ±3 bpm (non-motion condition)
Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: 0 ~ 150 BrPM
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
Accuracy: ±2BrPM or ±2% whichever is greater (7~150BrPM) Unspecified (0%~ 6BrPM)
- Apnea Alarm: 10 ~ 60 s
Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Dual-channel, provide T1; T2; ΔT
- Measuring and Alarm Range: 0.0 ℃~ 50 ℃ (32℉~ 122℉)
- Unit: Celsius (℃), Fahrenheit ( ℉)
- Resolution: 0.1℃or 1℉
- Accuracy: ±0.1℃(exclusive probe)
ECG
- Lead mode: 3/5 Leads, I, II, III, AVR, AVL, AVF, V
12 leads, I, II, III, AVR, AVL, AVF, V1, V2, V3,
V4, V5 and V6
- Protection: Breakdown Voltage 4000VAC 50/60Hz;
Defibrillator proof
- Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1),
20mm/mV (×2), 40 mm/ mV (×4), Auto
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
- Differential Input Impedance: >5 M ohm
- CMRR: Diagnostic Mode: ≥89 dB
Monitor Mode: ≥105 dB
Surgery Mode: ≥105 dB
Leakage Current: < 10μA
- ECG signal range: 12mV (Gain ×0.25)
- Accuracy: ±1bpm/ ±1%, whichever is greater
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
- Bandwidth: Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
- Indication of Electrode Separation: Every electrode
(exclusive of RL)
Heart Rate
- Measure range: Adult: 0, 15 ~ 300 bpm Neo/Ped: 0, 15 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1%
ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever
is greater
- Other range: unspecified
- Resolution: 0.01mV
NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode 1~480 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds
interval
- Measure and Alarm Range:
Adult: SYS: 40 ~ 280 mmHg DIA: 0 ~ 220 mmHg MEAN: 20 ~ 240 mmHg
Pediatric: SYS: 40 ~ 220 mmHg
DIA: 0 ~ 160 mmHg
MEAN: 20 ~ 170 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 0 ~ 110 mmHg
MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection via software &
hardware
EtCO2 (Mainstream/Sidestream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa
- Resolution: 0.1 mmHg
- CO2 Accuracy:
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25℃
- Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm
EtCO2 (Micro-stream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa
- Sample Rate: 50 mL/min ±10mL/min
- Resolution: 0.1 mmHg (0 ~ 50 mmHg) 0.25 mmHg (50 ~ 114 mmHg)
- CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 35℃)
- Respiratory Rate: Range: 3 ~120 BrPM Accuracy: ±1 bpm
IBP (Option)
- Max Channel: 2
- Measurement way: Thermal resistance way
- Press Sensor: Sensitivity 5 uV/V/mmHg, ±2% Impedance 300 to 3000Ω
- Resolution: 1 mmHg
- Unit: mmKg, kPa, cmH2O
- Transducer sites: Arterial Pressure (ART) Pulmonary Arterial (PA) Left Arterial (LAP) Right Arterial (RAP) Central Venous Pressure (CVP) Intracranial Pressure (ICP)
P1/ P2
- Measuring and alarm range:
ART 0 ~ +350mmHg
PA -10 ~ +120 mmHg
CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg
P1/ P2 -50 ~ +350mmHg
- Accuracy:
Static: ±1mmHg or ±2%, whichever is greater
(exclusive of transducer) ±4mmHg or ±4%, whichever is greater
(inclusive of transducer)
Dynamic: ±4mmHg or ±4%, whichever is greater
Cardiac Output (Option)
- Measuring Method: Right heart thermodilution
- Unit: °C/°F
- C.O. range: 0.1 l/min – 20.0 l/min
- C.O. accuracy: ±0.2 l/min or ±5%, whichever is greater
- Blood temperature range: 27℃- 43℃(80.6 °F - 109.4 °F)
- Blood temperature accuracy: ±0.1 ℃
- Injectate temperature: 0℃- 27℃(32 F – 80.6 F)
Alarm delay: <10s
Depth of Anesthesia (CSI) (Option)
- EEG sensitivity: ± 400μV
- Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
- CMRR: > 140 dB
- Input impedance: > 50 Mohm
- Sample rate: 2000 samples/sec, (14 bits equivalent)
- BS%: 0-100, filter 1-42 Hz, 1 sec. display update
- EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
- Alarms: High / Low with user selectable limit
- Artifact rejection: Automatic
- Sensor impedance range: 0 - 10 kOhm / measurement current
0.01 μA
Multi-gas/O2 (Anesthetic Gas) (Option)
- Method: Infrared absorption
- Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal, O2 (Optional paramagnetic sensor)
- Calibration: Room air calibration performed automatically
when changing airway
Airway adapt (< 5 sec)
- Measurement range:
CO2: 0~25%, N2O : 0~100%
O2: 0~100%, Enf, Iso, Hal: 0~25%,
Sevo, Des: 0~25%
- Data output: Fi and ET values
- Respiration rate: 0~ 150 BrPM
- Other: Up to 5 waveforms displayed Agent mixture detection MAC value displayed
* Specifications subject to change without prior 


Packing Details

49*34*46cm   8kg