Vital Signs Monitor MDW-ZWZF3 Specification Dimension: 210mm*130mm*75mm Weight: 1kg(excluding accessories) Voltage: AC100~240V, 50/60HZ Adapter: Output 9VDC, 5A 7" color TFT LED   Resolution: 800*480 pixels Type: Rechargeable lithium battery 7.4V/2200mAh Charge Cycle: ≥500...
+

Minimum quantity for "Vital Signs Monitor MDW-ZWZF3" is 1.

Port: Shanghai,China
Payment
Share to

Vital Signs Monitor MDW-ZWZF3

Specification

  • Dimension: 210mm*130mm*75mm
  • Weight: 1kg(excluding accessories)
  • Voltage: AC100~240V, 50/60HZ
  • Adapter: Output 9VDC, 5A
  • 7" color TFT LED  
  • Resolution: 800*480 pixels
  • Type: Rechargeable lithium battery 7.4V/2200mAh
  • Charge Cycle: ≥500 times
  • Working time: 2-3 hours (optional larger battery for 4-5 hours)
  • Method: USB External Thermal printer
  • Paper width: 50 mm (1.97 in)
  • Printing speed: 12.5/ 25/ 50 mm/s
  • Trace: Max. 3 tracks
  • Recording way: Real-time Recording, Review Printing,  
  • Level: Low, medium and high
  • Indication: Auditory and visual
  • Alarm volume adjustable
  • Alarm pause time: 1min, 2min
  • Parameter alarm type: Latch/ Unlatch
  • Touch screen (standard)
  • Touch pen (standard)
  • Ethernet Network: 1 standard RJ45 socket
  • USB Port: 1
  • Video Output: 1 HDMI port (option)
  • Temperature:  5 ~ 40 ℃
  • Humidity:  15% ~ 80% (non-condensing)
  • Atmosphere pressure:  86 KPa ~ 110 KPa
  • Temperature:  -20~50 ℃
  • Humidity:  10%~90%  (non-condensing)
  • Atmosphere pressure:  86 KPa ~ 110 KPa
  • IEC60601-1 Approved, CE marking according to MDD93/42/EEC
  • With reference to RoHS Directive 2011/65/EU recasting
  • Trend: 2160 hours
  • ARR events: 128 groups of ARR events and associated waveform
  • NIBP measurement reviewing: 2000 groups
  • Waveform review: 2 hours
  • Alarm event: 2000 groups of parameter alarms events and associated parameter
  • Measure range:
  • Resolution: 1 bpm
  • Accuracy: ± 1% or ± 1bpm, whichever is greater
  • Method: Oscillometric
  • Measure mode: Manual, Auto, STAT
  • Measure Interval in AUTO Mode 1~480 min
  • STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
  • Measure and Alarm Range: 
  • Static pressure accuracy: ±3mmHg
  • Resolution: 1mmHg
  • Accuracy: Maximum Mean error ±5mmHg           
  • Over pressure Protection: Dual protection via software & hardware 